water level gauge

water level gauge

Cangzhou, China
Production capacity:
1000 Ton / Month
Ada shi
Contact person

Basic Information

Place of Origin Hebei China (Mainland)
Brand Name Dachang
Model Number DC100-300mm
Application The spirit level is mainly used for checking flatness of guide ways of various machines and equipments.and horizontality or verticality of installation of equipment. A. Type Graduation 0.02mm/m Unit:mm B. ration The reading can only betaken as soon as the air bubble is completely fixed. The value indicated on the level is the slope of the basic length with one meter long. If it is necessary.to measure the real slope value of alength L,it may be calculated by the following equation: Real slope value =Scale X LXReading value For example,scale value=0.02mm/m.L=200mm.reading value (bubble movement)=2 divisions,then: Real slope value=0.02/1000X200X2=0.008mm. C. Adjustment Place the instrument on asteady and smooth even board,after the bubble fixed,the reading should be [a], then rotate level to 180 °, place it again on the original position and take the second reading [b] The Zeroerror of the level is 1/2(a-b). Then loosen the fastening screw on one side of the spirit hex wrench of 8mm into the eccentric adjuster and start the zero-setting by turning the adjustrer.At this time,if the instrument is found to incline to the rear,and vice versa. For over 5 degrees, or the deviation of the bubble exceeds half a graduation,it will be necessary to make readjustment by turning the two adjusters on both sides of the level untl the bubble does not move to and frowith the tilting of the indtrument:Lastly,it is also necessary to check whether the zero point deviates or not .If it nolonger deviates,then lock the fastening screw,thus completing the cycle of the zero-setting . Before using,clean the working surface of the level with gasoline and wipe it with absorbent cotton. .Temperature changes would cause measuring error,therefore it should be keptaway from heat source and airdrafts during measurement. . Reading should be takenonly after the bubble has come stable about 15 seconds after the level has been located on the test surface. Attention must be paid to the zerq adjustment and the parallelism of the working surface of the level in order to avoid the distortion in leveling .inspection and adjustment are neceasuring.

Delivery terms and packaging

Packaging Detail: Wooden box Delivery Detail: 7-30days after you order
Port: TIANJIN

Payment term

Letter of credit

Telegraphic transfer

Фотографии

    Password recovery
    To recover your password, please enter in the box below your email address with which you have registered:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    An error has occurred. Please check your e-mail address and try again.
    Ваш новый пароль:

    Name is empty


    Выберите страну доставки

    You have not written a message

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    Your message has been sent!

    Close

    1
    Рынок B2B
    Cancel Close
      Show more close
        Area search
        Worldwide
        Категории
          Product