Phase |
Three Phase |
Place of Origin |
China |
Brand Name |
Holley |
Model Number |
HLT01(DT862) |
Measuring Energy Range |
999999.9 |
Accuracy Class |
Class 2 |
Output Voltage |
100~415V |
Operating Temperature |
-30~70 |
Dimensions |
328x178x132.5mm |
1. General The HLT01 three-phase four-wire meter is designed to meet the latest IEC 60521 and BS EN 60521 standards for measuring active energy in three-phase four-wire alternating current power grids. Connection is direct or by instrument transformers. The average service life (MTTF) of the meter is 15 years and the maximal overload capacity is 400%Ib. 2. Constructions 2. 1 Meter case The meter case meets the protection requirements set by IP52 of IEC 60529. The series types of cases and terminal covers are available. 2. 2 Terminals & Terminal block Terminals: The connection terminals are made of nickel-plated brass with features of high mechanical strength, good conductivity and corrosion-resistance. Terminal block: For meter of steel or PC base, the terminal block is molded of heat- and flame-resistant Bakelite. The voltage test link can be located inside or outside of the meter case. 2. 3 Driving system It has three electromagnet elements. Each element consists of a voltage element and a current element, all of which are mounted on the meter frame with two screws. Voltage coil is enwrapped in a thermoplastic case to ensure fine insulation. The current element employs a simple and reliable load curve compensation mechanism to ensure the flat characteristic curve. An inductive load adjustment mechanism is on it. 2. 4 Rotor The rotor disk is made of hard and high purity aluminum. The rotor shaft is turned of high strength brass. There is a small hole on the upper end for storing lubrication and for fitting a brass bearing. The lower end is cone-shaped to ensure fine guiding of the rotor. 2. 5 Braking element The magnet cube is made of AlNiCo5 alloy and designed as U-shaped so that the effect of short time over currents upon the magnet is negligible. A temperature compensation plate made of a special alloy is mounted outside of the magnet. Precisely turning the adjustment mechanism can control the error of full load. 2. 6 Frame The frame is die-casted by high quality aluminum-silicon alloy of stable property to avoid distortion. The application of static spray-painting on the surface prevents the frame from oxidation. 2. 7 Upper bearing The guide pin is made of abrasion-proof stainless steel, and embedded into the brass sleeve. 2. 8 Lower bearing Both double jewel bearing and magnetic bearing are available. 2. 9 Register The cyclometer type register consists of six drums. The kWh can be read directly. The drum is made of polycarbonate. The framework is made of hard aluminum alloy and can be manually adjusted and fixed with two screws to insure the proper mesh with the worm on the rotor shaft. 3. Technical data 1 Meter type HLT01 (DT862) 2 Applicable Standards IEC60521 3 Accuracy class(according to IEC60521) CT operated: Class 2 Direct connected: Class 2 4 Average service life (MTTF)15 years 5 Basic current(Maximum current)A1. 5(6) 3(6) 2. 5(10) 5(10) 10(40) 15(60) 20(100) 6 Rating current of transformer in5A Direct connection 7 Reference voltage Un 3X57. 7/100V, 3X220/380V, 3X230/400V, 3X240/415V 8 Reference frequency 50 Hz, 60 Hz 9 Power losses in voltage circuit at 50 Hz, 1. 0 W/ 5VA 10 Power losses incurrent circuit at 50Hz Un Ib<0. 5 VA 11 Non-running with no-load 0. 8 1. 1Un 12 Starting current 0. 5%Ib 13 Mean temperature coefficient: From 0. 1Ib to Imax at unity PFFrom 0. 2Ib to Imax at unity 0. 5 lagging<0. 10%/oC<0. 15%/ oC 14 Insulation level: Withstand A. C. Voltage for 50 Hz, 1min Withstand impulse voltage 1. 2/50us>2 kV (when bakelite base>4kV)>6kV (when bakelite base>8kV) 15 Rated load torque at unity PF, Ib>850uNm 16 Weight of rotor54 g 17 Weight of meter=3. 1kg 18 Meter base Steel, Bakelite 19 Meter cover ABS, transparent PC, Bakelite 20 Terminal coverABS, Bakelite, PC 21 Register Cyclometer single, Unidirectional 22 OptionReverse running stopper