Certification |
CE |
Place of Origin |
Jiangsu China (Mainland) |
Brand Name |
skylight |
Model Number |
SLCLS |
Type |
Evacuated Tube |
Pressure |
Pressurized |
Circulation Type |
Direct / Open Loop (Active) |
Heating System |
Thermosyphon (Passive) |
Connection Type |
Split |
Installation |
Freestanding |
Split Pressurized Soar Water Heater. Components: Pressurized storage tank, heat pipe solar collector, working station and frame Skylight Manifold and Heat Pipe Specifications: Heat pipe wall thickness: 0.6mmLength and diameter of condenser: 55mm/14mmStart up speed: 30SStart up temperature: 25 oCInsulation: Polyurethane + Rock woolManifold casing material: Aluminum AlloyFrame material and thickness: Aluminum Alloy 1.3mmInlet Outlet: 22 or G3/4 inch compressionHeat pipe material: CopperInsulation: PolyurethaneRubber seals and rings: UV stabilized high temperature silicon rubberTest pressure: 9 barCollector mounting: Flat roof or inclined roofAngle of operation: 10degree-80degreeSkylight Pressure Tank Specs 1. Model: SLPWT 100, 150, 200, 250, 300, 400, 500L 2. Material and thickness of the inner tank: SUS3042B,1.8-2.5mm 3. Material and thickness of the outer shell: Color steel sheet 0.5mm 4. Insulation thickness: 40mm, 50mm 5. Surface area heat exchanger top: 0.4 m2 -0.7m2 6. Surface area heat exchanger bottom: 0.6-0.9 m2 7. Installation size of water pipe: NPT3/4" 8. Back-up: 2KW-3KW 9. Working pressure: 0.6Mpa Working station information 1. It includes controller, Wilo pump and expansion vessel and other needed accessories. It controls the whole system. 2. There are single pipeline and double pipelines two types, 3. Single pipeline: SP106, SP116 and SP118 4. Double pipelines: SP226, SP228 and SP328 Working Principle 1. Skylight Temperature difference circulation: When the temperature difference between collector and tank reaches the setting starting value, the circulation pump start working to exchange the heat. When the temperature difference reaches the programmed shutdown value, the circulation pump will stop working. 2. Skylight Frost circulation: When the collector temperature drops below the programmed frost protection value, the circulation pump start working. When the tank temperature drops below 4 degree, the auxiliary heating element starts to heat the water till 20 degree, and close the auxiliary heating element. When the collector temperature rises to 7 degree, the circulation pump will stop working. 3. Skylight Auxiliary heating: When the temperature of the water at the top of tank drops below the programmed opening value, the auxiliary heating element starts to work. When it rises to the programmed closing value, the auxiliary heating element will stop working. Three different heating periods can be set every day. High temperature protection: When the collector temperature rises to the programmed maximum value, the emergency shutdown function will start and the circulating pump will stop, in order to avoid damaging the solar system components because of high temperature. 4. Skylight Cooling protection: When the collector temperature rises to the maximum value, the circulation pump starts to work, until the collector temperature drops or the tank temperature rises to 95 degree. (Tank emergency shutdown temperature)