Single-phase Electronic Multi-tariff Carrier Wave

Single-phase Electronic Multi-tariff Carrier Wave

Qingdao, China
Production capacity:
30000000 Piece / Year
Qingdao, China
Company
86-532-80663550
Michael Hu
Contact person

Basic Information

Display Type Analog and Digital
Phase Single Phase
Place of Origin Shandong China (Mainland)
Brand Name Techen
Model Number DDSIF3699
Measuring Energy Range 0-999999.9
Accuracy Class Class1
Output Voltage 110V; 220V; 230V; 240V
Operating Temperature -30 ℃ ~ +70 ℃
Application DDSIF3699 single-phase electronic multi-tariff carrier energy (hereinafter referred to as "Instrument") is mainly used for measuring time-sharing billing of civilian electricity so as to better balance network load. LCD display with the active energy measurement, infrared communication, power line carrier communication, remote control power-on and power-off, automatically freeze energy amount at daily 0:00 and freeze energy amount each hour within 24 hours. The instrument is the terminal device of a remote automatic meter reading system, which can accurately measure user's active energy. As well it adopts Low Power Line as communication medium, maintain reliable communication link with the concentrator in the substation and transmit data to concentrator. It is the ideal choice for residents to use electricity and remote meter reading. Comprehensive technical specifications of the instrument accord with the People's Republic of China national standard GB/T17215-2002 "1-and 2 static AC Power Meter" requirements, infrared communication line DL / T 645-1997 "multi-function meter communication protocol" requirements. Consistent with the PRC power industry standard DL / T 698-1999 "meter reading system technological conditions for LV users”Functions and features* the total active power and peak, normal and least energy measurement * Active power measurement in positive and negative direction, reverse-active power accumulated to the positive active power consumption. * Power line remote automatic meter reading. * By ways of software expansion of spectrum to realize power line carrier communication, accurate, reliable, high meter reading ability. * Mutual Auto relay function. * Capacity storage: Daily 0:00 consumption freeze. * Multi-rate function: can set four kinds of rates of sharp, peak, shoulder, off-peak and 14 time intervals by programming. The time intervals can cross 0:00. The minimum time interval is 15 minutes. The actual start and end time of any time interval and preset time error should be less than 5s. * Freeze settlement functions, save electricity amount of 0:00 and the latest three months. * Remote control power-on and power-off function. * IR programming, Power Line Carrier programming optional. * Infrared communication: through the infrared port realize function of instrument programming and meter reading. * Can freeze energy amount of each o’clock within 48 hours * Hardware clock RX-8025 control programs, time and date can be set, you can broadcast commands to correct the time. * No need response when broadcast time correction unless the time difference between master and secondary calendar and clock within the ± 5min. The broadcast time adjustment can only be implemented once every day. * LCD display, display with backlight and can indicate power-off on display.* Input and output interfaces:1. Passive impulse output interface with opt coupler isolation 2. Infrared remote control programming and meter-reading interface, refer to DL / T 645-1997 standard 3. Daily timing error detection signal output 4. Time period switching signal outputSpecifications and main technical parameters * Rated voltage: 220VCurrent Constant imp/kWhCurrentConstantImp/kWh1.5(6)A64005(50)A16005(20)A320015(60)A80010(40)A160020(80)A800* Rated frequency: 50Hz * Accuracy class: Active 1.0, 2.0 * Starting Current: 0.4% (1.0), 0.5% (2.0) Basic current * Creeping: logically design with anti-creeping * Communication channel: two-way low voltage power line, two-way infrared communications * Clock error: ≤ 0.5s / day (23 °C) * Product design life:> 10 years * Display: LCD * Power: Line power voltage ≤ 1.5W/6VA, current line power ≤ 2VA * Environmental conditions: standard operating temperature is -30 °C +70 °C * Limit working temperature: -45 °C +70 °C * Relative humidity: ≤ 75%

Delivery terms and packaging

Port: Qingdao

Payment term

Letter of credit

Telegraphic transfer

Фотографии

    Password recovery
    To recover your password, please enter in the box below your email address with which you have registered:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    An error has occurred. Please check your e-mail address and try again.
    Ваш новый пароль:

    Name is empty


    Выберите страну доставки

    You have not written a message

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    Your message has been sent!

    Close

    1
    Рынок B2B
    Cancel Close
      Show more close
        Area search
        Worldwide
        Категории
          Product