Basic Information

Place of Origin Shanghai China (Mainland)
Brand Name ACREL
Model Number PZ-M32
1. General PZ-M32 is applicable in intelligent systems remotely measuring analog signals, like current, voltage, power, temperature, pressure and humidity etc... PZ-M32 can accept 32 ways AC/DC 4-20mA / 0-20mA or AC/DC 0-5V analog signals. It is connected to master device or the computer by RS485 communication to transfer the data on a real-time. It has 32 alarms LED with 3 colors to indicate the state of 32 analog inputs. We can set 2 points alarms (maximal and minimal value) as well as the delay of the alarm. 2. Technical feature - Input 32analog signals Signal type 0/4-20mA AC/DC or 0-5V AC/DC Scanning time ≤1s - Power Supply Voltage range 24 VDC(18-36VDC) or AC/DC 80-270V Consumption ≤ 5W - CommunicationBus Mode 2-wires half-duplex RS485/Modbus protocol Bus Capacity ≤ 32 Response Time 20ms Baud rate 9600 / 4800 / 2400 / 1200 bps - Capacity of Sequence of Events (SOE) ≤1600 - Degree of Protection IP40, Terminal IP20 - Isolation 2Kv/1min,50Hz ( inputs, output and supplier) - Work Temperature -5C - 55C - Storage Temperature -25C - 85C - Mounting TS35 Standard DIN rail - Dimention 160 × 50 ×110mm - Standards IEC61000-4-2: 1995 Electrostatic discharge immunity test Level 3 IEC61000-4-3: 1995 Radiated, radio-frequency, Level 3 electromagnetic field immunity IEC61000-4-4: 1995 Electrical fast transient pulse immunity test Level 3 IEC61000-4-5: 1995 Surge immunity test Level 3 EN55022: 1998 Information technology equipment(ITE) Level B 3.The description of LED for analog input alarm PZ-M32 can indicate the states of all the analog inputs. By 2 Rs485 communications, we can set maximal and minimal values alarms as well as the delay of alarms. It has 32 LED with 3 colors to match each analog input. Description LED: OFF: no input Green: work well, the analog input value is between maximal and minimal alarms. Red: on the state of maximal value. Orange: on the state of minimal value. 4. Examples Examples1Read 1st channel analog value on device02 (by order 03H)Request: 0x02,0x03,0x00,0x0D,0x00,0x01,0x15,0Xc9Reply: 0x02,0x03,0x02,0x13,0x00,0Xb5,0x74Explanation: On device02, its 1st analog input value is 4.864.Examples2Set the maximal value of 1st alarm on device01 (by order 06H)Request: 0x01,0x06,0x00,0x2D,0x3E,0x80,0x09,0xC9Reply: 0x01,0x06,0x00,0x2D,0x3E,0x80,0x09,0xC9Explanation: set the maximal value of 1st alarm as 16.000Examples3Read the states from 1st channel to 5th channel on device01 (by order 02H)Request: 0x01,0x02,0x00,0x00,0x00,0x05,0xFC,0x09Reply: 0x01,0x02,0x01,0x0C,0x51,0x8DExplanation: 0C to binary is 01100. That’s to say that there are 2 alarms, channel 3rd, 4th. Others work normally.

Delivery terms and packaging

Packaging Detail: PACKED BY CASE Delivery Detail: 2 WEEKS
Port: SHANGHAI

Payment term

Letter of credit

Telegraphic transfer

Фотографии

    Password recovery
    To recover your password, please enter in the box below your email address with which you have registered:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    An error has occurred. Please check your e-mail address and try again.
    Ваш новый пароль:

    Name is empty


    Выберите страну доставки

    You have not written a message

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    Your message has been sent!

    Close

    1
    Рынок B2B
    Cancel Close
      Show more close
        Area search
        Worldwide
        Категории
          Product