PVC cable

PVC cable

Ningbo, China
Production capacity:
500 Kilometer / Month
Ningbo, China
Company
0086-574-86198928
Thomas Zhou
Contact person

Basic Information

Place of Origin Zhejiang China (Mainland)
Brand Name KUKUN
Insulation Material PVC
PVC cable1). Standard: IEC60502, GB/T 127062). Voltage: 0.6/1kV3). Specification:Type DesignationApplicationsVV VLVCopper conductor, PVC insulated, PVC sheathed power cableAluminium conductor, PVC insulated, PVC sheathed power cableFor laying indoors, in tunnel or cable trench, unable to bear external mechanical forces. Single core cable is not permissible to lay in magnetic duct.VYVLYCopper conductor, PVC insulated, PE sheathed power cableAluminium conductor, PVC insulated, PE sheathed power cableVV22VLV22Copper conductor, PVC insulated, steel tape armoured, PVC sheathed power cableAluminium conductor, PVC insulated, steel tape armoured, PVC sheathed power cableFor laying indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force.VV23VLV23Copper conductor, PVC insulated, steel tape armoured, PE sheathed power cableAluminium conductor, PVC insulated, steel tape armoured, PE sheathed power cableVV32VLV32Copper conductor, PVC insulated, steel wire armoured, PVC sheathed power cableAluminium conductor, PVC insulated, steel wire armoured, PVC sheathed power cableFor laying indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force.VV33VLV33Copper conductor, PVC insulated, steel wire armoured, PE sheathed power cableAluminium conductor, PVC insulated, steel wire armoured, PE sheathed power cableNote: The armoured single core cables is only used for D.C. system. As for A.C. system, non-magnetic armour material should be applied.4). Nominal cross-sectional areas: 1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2, 800mm25). Production range: Single core cable from 1.5mm2 to 800mm2; Multi-core cable from 1.5mm2 to 400mm2.6). Operating characteristics: Rated power-frequency voltage U0/U:0.6/1kV Max.permissible continuous operating temperature of conductor:70 oC Max.short-circuit temperature of the conductor shall not exceed(Max.5 seconds duration): cross-section of conductor≤300mm2-160 oC; cross-section of conductor300mm2-140 oC. The ambient temperature under installations should not be below 0 oC. The bending radius of single core cable should not be less than 20 times of the cable diameter; the bending radius of multi-core cable should not be less than 15 times of the cable diameter.

Delivery terms and packaging

Port: NINGBO

Payment term

Letter of credit

Telegraphic transfer

Фотографии

    Password recovery
    To recover your password, please enter in the box below your email address with which you have registered:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    An error has occurred. Please check your e-mail address and try again.
    Ваш новый пароль:

    Name is empty


    Выберите страну доставки

    You have not written a message

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    Your message has been sent!

    Close

    1
    Рынок B2B
    Cancel Close
      Show more close
        Area search
        Worldwide
        Категории
          Product