Place of Origin |
Zhejiang China (Mainland) |
Brand Name |
CNRUIHUA |
Model Number |
CPU Module LM3105 |
CPU FeaturesLocal I/O 8 Channels DC24V DI, 6 Channels Relay DOExpandable I/O 2 modules (unable to connect Ethernet modules) High-speed counter Monophase counter: 3 points, 100KHz Biphase counter: 2 points, ints, 100KHz Pulse output N/A Pulse catch 2 points Interrupt input 2 points Analog potentiometer 2, value setting range 0∼255 User program memory capacity 28K bytes Retain area N/A Input data memory 256 bytes <>Output data memory 256 bytes Mid-variables memory 1K bytes Global memory 2K bytes PasswordPassword Yes Real-time clock N/A Timer No limit (1ms as minimum unit) Counter No limit (Maximum counting range: 16 bit) Basic instructions 283 Function blocks Over 70 Operation speed 0.65μs (Basic instruction) Power Supply SpecificationsPower supply 220V AC@50Hz Allowed range 187V AC∼242V AC@50Hz Current consumption (MAX) 120mA Output voltage 24V DC Allowed range 22.8V DC∼25.2V DC Current output +24VDC (To expansion bus) 260mA +24V DC (To the outside) 200mA +5V DC (To expansion bus) 800mA Short circuit protection 400mA, 24VDC output Communication FeaturesCommunication interface 1 RS-232 (Non-isolating) Communication protocol Proprietary protocol/MODBUS/Free protocol Input FeaturesInput type Sink/Source Input voltage rated value 24V DC Allowed range 0V DC∼30V DC Logic 1 signal 15∼30V DC, allowed minimum current 3mA Logic 0 signal 0∼5V DC, allowed maximum current 1mA Input delay time <0.6ms (Rated input voltage) Isolation mode Photocoupler isolation Isolation group 2 groups Maximum Isolation Voltage 1500VAC Output FeaturesOutput type Relay Output voltage 24V DC or 24 V AC ∼230V AC Allowed range 5V DC∼30V DC or 5V AC∼250V AC Common end output current total <10A Output switch capacity 2A, resistance load Minimum load 10mA (contact voltage 5VAC or 5VDC) Over current protection N/A Contact impedance <0.2Ω Isolation group 2 groups Isolation voltage between coil and contact 3000VAC, 1 minute, leakage current 1mA Isolation voltage between contacts 750VAC, 1 minute, leakage current 1mA Isolation resistance (minimum) 100MΩ (under 500VDC) between contacts&lacts</p> or between coil and contact Contact switch delay time <10ms Contact switch frequency (maximum) 1Hz Relay mechanical life No load: over 10,000,000 times; Rated Resistive load 2A: over 100,000 times Physical FeaturesDimensions 125mm(L)×90mm(W)×70mm (H) Weight <350g &ong>1.PLC systems,industrial controller,logic controllers1.PLC process coocess control, industrial controller,PLC direct,PLC ,electronic date systems ,programmable controller,keyence plc,programmable automation ,PLC ladder,micro PLC,modbus,PLC application,logic analyzer,pid controller,bradley plc 2.CE approved 3.reasonable price and high quality