Metal-enclosed Medium Voltage Switchgear

Metal-enclosed Medium Voltage Switchgear

original price: 10 000 USD
Shanghai, China
Production capacity:
500 Set / Month
Shanghai, China
Beginner
86-21-33521117
Brian Chueng
Contact person

Basic Information

Place of Origin Shanghai China (Mainland)
Brand Name CHFE
Model Number XGN-12
Standards GB3906 A.C. metal-enclosed switchgear for rated voltages above3 kV and up to and including35 kV IEC298 A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV Service condition 1. Ambient temperature: -15'C +40'C 2. Altitude: <=1000m 3. Air humidity: daily average of Air humidity<=95%, daily average of partial vapor pressure <= 2.2kPa; monthly average of Air humidity<=90%,monthly average of partial vapor pressure <= 1.8kPa 4. Earthquake intensity <= 8 degree 5. No corrosive or flammable gas Special condition subject to users Features and Benefits 1. 3to 35kV rated maximum voltage. 2. Easy-to-read controls and indicators, an easily inspected primary disconnect, contact erosion indicator and precisely tooled breaker mechanisms. A lower compartment roll-in breaker is available for indoor or walk-in outdoor switchgear. 3. Simplified maintenance and training. For example, all breakers are the same size, and most frame parts, primary conductors, disconnects and mechanisms are interchangeable. 4. The main bus compartment is completely isolated by 11 gauge metal barriers. Bus bars insulated with high dielectric epoxy pass through trackresistant polyester glass barriers between cubicles. 5. The secondary disconnect combines the contact reliability of a plug with the self-aligning convenience of sliding contacts. 6. Current transformers are located behind mechanically actuated safety shutters and a barrier that isolates the primary disconnect as the breaker is moved into the disconnect position. 7. Voltage transformer trays are automatically grounded on withdrawal, which provides isolation from primary connections. 8. Dry type control power transformers are insulated with molded resin epoxy and mounted in a drawout tray for easy access. 9. Even two-breaker vertical sections offer ample space for terminating up to two 750 MCM cables per phase. 10. ABB, Schneider, GE circuit breaker optional. Rated voltage kV 3.6, 7.2, 12 Rated current A 630 4000 Rated short-circuit breaking current kA 16, 20, 31.5, 40 Rated short-circuit making current (peak) kA 40, 50, 80, 100 Rated peak withstand current kA 40, 50, 80, 100 Rated short time withstand current kA 16, 20, 31.5, 40 Insulation Rated withstand voltage at working frequency (1min) Phase to earth kV 24, 32, 42 Between open contacts kV 24, 32, 48 Rated lightning impulse withstand voltage Phase to earth kV 40, 60, 75 Between open contacts kV 46, 70, 85 rated short-circuit duration s 4 Protection level IP2X Connection type Single bus section, single bus with bypass Operators Electromagnetism, energy storage spring Dimension (W*D*H) mm 1100*1200*2650 Weight kg 1000

Delivery terms and packaging

Packaging Detail: Wooden case Delivery Detail: 25 days
Port: Shanghai

Payment term

Letter of credit

Telegraphic transfer

Фотографии

    Password recovery
    To recover your password, please enter in the box below your email address with which you have registered:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    An error has occurred. Please check your e-mail address and try again.
    Ваш новый пароль:

    Name is empty


    Выберите страну доставки

    You have not written a message

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    Your message has been sent!

    Close

    1
    Рынок B2B
    Cancel Close
      Show more close
        Area search
        Worldwide
        Категории
          Product