LCD Surface Resistance Meter

LCD Surface Resistance Meter

Shenzhen, China
Production capacity:
100 Set / Day
Shenzhen, China
Company
86-755-27385248
Alan Zheng
Contact person

Basic Information

Place of Origin Guangdong China (Mainland)
Brand Name STACLEAN
Model Number STC-008
Accuracy Class +/-5%
Dimensions 98*186*28MM
LCD SURFACE RESISTANCE/RESISTIVITH TEST KIT Model:STC-008* Tests at 10 or 100 Volts, and has Measurement Range Between 103 and 1012 Ohms* Use to satisfy ANSI/ESD S20.20 test equipment requirement to measure RTG RTT and Resistivity * Complete test kit has everything necessary, including rigid carrying case,5lb, electrodes &leads * Dual test voltage-10 or 100 Volts designed in accordance with ESD S4.1,ANSI ESD7. 1,and ANSI EOS/ESD S11. 11 test measurement procedures * Portable ideal for field technician. * Two built-in parallel probes on bottom of unit measure surface resistivity * Range: 103-1011 ohms @ 10 V and 106-1012 ohms @ 100 V * Note :Test material less than 106 at 10 Volts If resistance of material to be tested unknown first test at 10 Volts Configuration: l One calibrated ohmmeter l Two shield measuring line l Two 5 lb heavy hammer l One adapter with 12V stable power l One rigid portable leather case Feature: l Voltage: 10V and 100V l Measurement Range: 103-1012 ohms l Precision: +5% l Power supply: 9V dry cell (PP3); 12V stable adapter l Size: 98 * 186 * 28 (mm) l Instruments weight: 300 g l Complete kit weight: 6800 gInstruction: 1) Turn the switch above at 10V and then press the red button before using 10V to measure the surface resistance of the material. Turn the switch below at 100V and then press the red button before using 100V to measure the surface resistance of the material. 2) Display way: The surface resistance shall display on LCD, ohm as the unit. Such as: 1.2 * 103 shall be displayed as 1.2 E 3, namely: 1,200 ohms 3) Measurement Range: 103 106 (range of conduct electricity) it shall be more correct to measure at 10 Volts. 106-1012 (anti-static range) it shall be more correct to measure at 100 Volts. >1012insulation rangeit shall be more correct to measure at 100 Volts. 4) Measurement with two electrodes: Before measuring, lay the two electrodes at bottom of instrument evenly on the surface of measured material, press the red button. Measurement with heavy hammer: Before measuring, insert one end of two connections to the jack (external probes) at the front instrument. Insert the other to the jack above the heavy hammer. Meanwhile, the electrode below the instrument is cut, lay the heavy hammer on the surface of the measured material evenly and press the red button.

Delivery terms and packaging

Packaging Detail: 1 sets/per BOX Delivery Detail: 10days

Payment term

Letter of credit

Telegraphic transfer

Фотографии

    Password recovery
    To recover your password, please enter in the box below your email address with which you have registered:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    An error has occurred. Please check your e-mail address and try again.
    Ваш новый пароль:

    Name is empty


    Выберите страну доставки

    You have not written a message

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    Your message has been sent!

    Close

    1
    Рынок B2B
    Cancel Close
      Show more close
        Area search
        Worldwide
        Категории
          Product