Hysteresis loop tracer

Hysteresis loop tracer

Loudi, China
Beginner
0086--738-8319167
Anna Zeng
Contact person

Basic Information

Place of Origin Hunan China (Mainland)
Brand Name Linkjoin
Model Number MATS-2010H
Automatic measurement of the demagnetization curve of permanent magnetic material such as ferrite, AlNiCo, NdFeB, SmCo, etc. Accurate measurement of the magnetic characteristic parameters of remanence Br, coercive force HcB, intrinsic coercive force HcJ and maximum magnetic energy product (BH)max. Windows measurement software applied simply. The product conforms to China National Standards GB/T 3217-92, GB 11209-89 and international standard IEC 404-5. Adopt ATS structure, users can customize different configuration as required: According to the intrinsic and size of measured sample to decide the electromagnetic size and corresponding testing power supply; Select different measuring coil and probe according to the option of measuring method. Decide to whether choosing fixture in accordance with sample shape. Decide to whether selecting heating installation or not according to the test requirement. General Features ·Automatic measurement on saturation hysteresis loop and magnetic characteristic parameters of generally permanent-magnet material such as Ferrite, Rubber & Plastic Magnet and AlNiCo, Js, Br, HcB, HcJ, (BH)max and μrec. ·Automatic measurement on demagnetization curve and magnetic characteristic parameters of rare earth permanent-magnet materials such as NdFeB and SmCo, etc. At the second quadrant: Br, HcB, HcJ, Hk (H90) and (BH)max. ·Test sample shapes: circular ring, round cake, square, tile and other irregular shapes. ·Adopt B coil + fluxmeter to measure magnetic induction, zero shift of integrator can be self-corrected through software. ·Adopt J coil + fluxmeter to measure magnetical polarization, remnant coil area of J coil can be automatically compensated through software. ·Magnetic field intensity can be measured with Hall magnetometer, nonlinear error of hall probe can be corrected through software, within 0 2.4 T range, nonlinear error can be controlled within ±0.2%. ·Adopt H coil + fluxmeter to measure magnetic field intensity, Hall magnetometer only used to indicate zero point of magnetic field so as to thoroughly eliminate nonlinear error of hall probe. ·Optimal range of field voltage, fluxmeter and magnetometer can be automatically set up. ·Magnetization, testing and demagnetization of general permanent magnetic sample can be completed at one time, time set up 20 seconds 60 seconds. ·Rare earth permanent magnetic samples need saturation magnetizing before testing, testing time 60 seconds 120 seconds. ·The sample after testing can be in a state of demagnetization or magnetizing, freely selected buy users. ·Select heating head and temperature controller to detect magnetic characteristics of Ferrite, AlNiCo and rare earth material under high temperature (maximam 220°C). ·Select shoe jig for direct measurement on magnetic shoe. System Specifications Test AlNiCo standard sample, measuring error on entire magnetic hysteresis cycle estimated: B: 1%, H: 1% Parameters measuredBr (%)HcB (%)HcJ (%)(BH)max (%)Uncertainty (k = 2)1112Repeatability (constant temperature)± 0.3± 0.3± 0.3±1 Instrument Specifications TPS-2000H Test Power SupplyDCT150 ElectromagnetOutput Voltage: 0 ±100 V Output Current: ±20 A (maximum value) Stability: superior to 0.05% Output protection: overvoltage, overflowing, short-circuits protectionHead Diameter: 150 mm shrink to 80 mm Head Spacing: 0 50 mm (continual adjustable) Maximal Magnetic Field: 2.4 T (head spacing 10 mm, coilcurrent 30 A)LZ-210B FluxmeterDCT200 ElectromagnetRange: 2.5, 5, 10, 20 mWb Full Range Precision: 0.5% Zero Shift: 2 μWb / 30 seconds (2.5 mWb)Head Diameter: 200 mm shrink to 80 mm Head Spacing: 0 50 mm (continual adjustable) Maximal Magnetic Field: 2.7 T (head spacing 10 mm, coil current 60 A)LZ-210H MagnetometerDCT250 ElectromagnetRange: 0.5, 1, 1.5, 3 T Full Range Precision: 0.5% Non-Linearity: ±0.2% (software correction)Head Diameter: 250 mm shrink to 80 mm Head Spacing: 0 80 mm (continual adjustable) Maximal Magnetic Field: 2.8 T (head spacing 10 mm, coil current 60 A)DCT130 ElectromagnetPC6023 A/D D/A cardHead Diameter: 130 mm Head Spacing: 0 50 mm (continual adjustable) Maximal Magnetic Field: 1.5 T (head spacing 10 mm, coil current 20 A)A/D Conversion: 12 bits,32 channels Conversion Time: < 10 μs Conversion Accuracy: 0.1% (full range) D/A Conversion: 12 bits, 2 channels Conversion Accuracy: 0.1% (full range)

Delivery terms and packaging

Port: Huang Gang Port, Shen Zhen

Payment term

Letter of credit

Telegraphic transfer

Фотографии

    Password recovery
    To recover your password, please enter in the box below your email address with which you have registered:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    An error has occurred. Please check your e-mail address and try again.
    Ваш новый пароль:

    Name is empty


    Выберите страну доставки

    You have not written a message

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    Your message has been sent!

    Close

    1
    Рынок B2B
    Cancel Close
      Show more close
        Area search
        Worldwide
        Категории
          Product