Place of Origin |
Other |
Brand Name |
Cummins |
Model Number |
SFC450K |
Speed |
1500 r/min |
Frequency |
50 Hz |
Rated Power |
500 kva |
Rated Voltage |
220V-380V/400V |
Rated Current |
855 amps |
Output Type |
AC Three Phase |
Cummins diesel generating set model : SFCD450K Frequency of generator:50Hz Continuous power400kw(500kva)Output voltage380/440V Standby power450kw(563kva)Rate Speed1500r/min Price of generator: USD EXW SINGFO USD FOB SHENZHEN Technical parameters of generator Power factorCOSΦ=0.8lagging Start modeElectric Noise level :80-100dB Packing dimension3410*1260*1980MML*W*H Fuel consumption:92.1L/H(101.6L/H) Weight4150Kg Rated currency(amps)855amps ProtectionLow oil-pressure, High water temperature, Over-speed, Over-current. Technical parameters of diesel generator: BrandCumminsPower(50Hz)450kw ModelKTA19-G4OriginalChina Cylinders6Cylinders LayoutLine Fuel0# light dieselVoltage ControlAVR Start modeDC24V electric startOverload110% Inter-CoolingAir inter-coolingDisplacement18.9L Speed-Governing ElectricSteady Speed Droop≤1% Technical parameters of Alternator: BrandStamford ProtectionIP21 ModelHCI544DOriginalChina Frequency fluctuation≤±0.5 %Frequency regulation≤±0.5 %stable Voltage distortion4%Voltage controlAVR Technical parameters of Control Panel: BrandUPWIN 2210 Start or Stop Generator set manually/ AutomaticallyGenerator over/under frequency protection Open controller output can be defined as Pre-heat/Idle output dieselgenerator set over/under/unbalance voltage Protection High Coolant temperature protectionOver speed protection Low Oil pressure protectionOver speed protection Over load protectionAvailable for remote control Noteindicate this function depend on the set points of the controller in field *Standard Accessories* 1. Accessories. The standard accessories Single-bearing generator again drops. IP21. Insulation H Radiator for 50 ambient temperature and double-deck cooling The Electric start and 24v charger Regulator Standard air filter Automatic control panel Storage battery Switch for out-wire Steel base-frame against vibration Soft pipe for fuel and handle for lube going-out Operation manual Plastic packing 2. Testing conditions. Standard Air Intake Temperature 25ºC Air Intake Pressure 100kpa Standard Light Diesel 0# or 10# Light diesel Fuel Intake Temperature 40ºC Air Intake Restriction 254mmHg Exhaust Back Pressure 76mmHg Lubricant Oil 15W40-CF4 Upgrade 3. Operation ofgenerator Continuous power: operate continuously for 24h in a day. 10% overload for An hour is allowed in a 12 hours. Standby power: this is used only when the civil power is off. Overload is not allowed. *Optional Accessories* It is necessary to pay additional if you need these accessories as follows: ATS (Automatic transfer switch) ATS is such a system that can exert the function automatically by transferring two circuits to recover power supply while powering off, in stead of manual work. MCCB (Breaker) Battery charger Power factorCOSΦ=0.8lagging Start modeElectric Noise level80-100dB Packing dimension3410*1260*1980MML*W*H Fuel consumption:92.1L/H(101.6L/H) Weight4150Kg Rated currency(amps)855amps ProtectionLow oil-pressure, High water temperature, Over-speed, Over-current. :