Place of Origin |
Zhejiang China (Mainland) |
Brand Name |
GACIA |
Model Number |
GAS1-250A |
Type |
Moulded Case |
Poles Number |
3 |
Application of MCCB 1.GAS1 Series Moulded CaseCircuit Breaker ( here in after referred to be as MCCB) is the new series MCCB, Which is developed strictly according to international standards and manufactured with advanced technology by GACIA Electrical Appliance CO., LTD. This product complies with IEC60947-2, GB14048.2 2.The Air Circuit Breaker, having rated insulation voltage 500V(Inm≤160A) to 690V(Inm≥250A) is designed to be used for distribution network of having rated current to 10A to 1600A, rated operational voltage 380/400V to 660/690V, intended for power distribution, protection of electrical equipments and circuits against overload, short-circuit and under voltage, and also for unfrequent switching of electric circuits in most cases. MCCB with frame rating up to and including 400A can be used for unfrequent starting, and interruption of squirrel cage motors, for protection of motors against overload, short-circuit and under voltage. 3.GAS1 series circuit breaker can be equipped with electric accessories and mechanical accessories, such as under voltage release, shunt release, auxiliary contacts, alarm contacts, electric operating mechanism and rotary mechanical operating handle etc. 4.GAS1 Series intelligent moulded case circuit breakers are equipped with electronic release with the function of protection of electric circuits and equipments not only against overload, short circuit and under voltage, but also against earthing failure. The intelligent function of it are: current beam indication of operation; indication of power of source and self-diagnostic indication of pre-alarm and alarm for over-current failure; output of over-current signal and monitoring of circuit breaker open/ close, particularly, the intelligent trip unit is designed with interface available for remote measuring, remote adjusting, remote controlling and remote communicating between circuit breakers and computers. Technical data and performance Model numberGAS1 N-250 GAS1 S-250 GAS1 H-250GAS1 N-400 GAS1 S-400 GAS1 H-400Rated current of frame size Inm (A)250400Rated current In (A)125 160 200 250250 315 (350) 400Rated insulation voltage Ui690V690VRated operational voltage Ue400V/415V400V/415VNumber of poles3 43 4Rated current of the N Pole=In=InAC400V/50Hz O-CO(Icu) (KA) Rated ultimates short-circuit breaking capacity355065355065AC400V/50Hz O-CO-CO(Ics) (KA) Rated service short-circuit breaking capacity3537.548.753537.548.75(peak)cos AC400V/50Hz(Icw) Rated short-circuit making capacity73.5/0.25143/0.2 187/0.273.5/0.25143/0.2187/0.2AC400V/50Hz 1s(Icw) (KA) Rated short-circuit withstand current_5(Uimp) (V) Rated impulse withstand voltage80008000Dielectric property (V)30003000Enduence (times)Total cycles80005000Electrical endurance10001000Mechanical enduance70004000Flashover distance (mm)≤100≤100Over current trip unit Heat magnetic releaseintelligent trip unitM typeH typeUtilization categoryMain circuitA/BA/BAuxiliaryAC-15AC-15outline dimensionsW (mm)3P 4P105 140140 184L (mm)3P 4P170/254 170/254254 254H (mm)3P 4P103.5 103.5103.5 103.5Weight (kg)Fixed version 3P/4P2.7/3.54.1/5.55.1/7.1Plug-in version 3P/4P3.2/4.24.6/66.2/8.5Draw-out version 3P/4P3.6/4.65/6.46.5/8.7