FUVS100 Flame Detector

FUVS100 Flame Detector

original price: 27,00 USD
Beijing, China
Production capacity:
10000 Piece / Month
Beijing, China
Anonymous
86-010-51655362
13701089084
Peter Lee
Contact person

Basic Information

Place of Origin Beijing China (Mainland)
Brand Name Green Island
Model Number FUVS100
Usage Fire
APPLICATION: The FUVS series Ultraviolet Flame Detectors detect the ultraviolet radiation emitted by combustion flames. The flame detectors are used with GreenIsland flame safeguard controls to provide flame supervision for gas, oil, or combination gas-oil burners. Sensitive Range:190 - 270 nm Parallel Using: Two Flame Detectors can be wired in parallel for difficult flame sighting installations. Model Selection: Model ConnectionMountingViewingTemperatureProtection FUVS1001.5m wiresG1/2''End-15°C - 100°CIP65FUVS110 terminal with 0.5m wiresFlangeSide0°C - 60°CIP65 FUVS200 1.5m wiresG3/4"End-15°C - 100°CIP65 FUVS225 1.5m wiresG1"End-15°C - 100°CIP65 Mount The Detector: Mount the detector onto the sight pipe. Make sure theflange gasket is in place inside the mounting collar on the detector, and then screw the collar onto the sight pipe or fitting. NOTE: If a window is installed between the UV detector and the flame, it must be fabricated from quartz or fused silica. Ordinary glass filters out ultraviolet radiation. Sight Pipe Ventilation: It may be necessary to ventilate the sight pipe to cool the flame detector or to clear the sight pipe of UV radiation absorbing substances such as smoke, excessive moisture or, in some instances, unburned fuel. FUVS Wiring Connection: Attention: – Please use as short as possible wire to connect the UV detector to controller. – Do not run the flame detector wiring in the same conduit with high voltage ignition transformer wires. – If the wires are not long enough to reach the terminal strip or wiring sub-base, the using wire should be suitable for at least 105°C and 1mm2. –The total length, from UV detector and controller, should be lease than 100m –The blue wire must be connected to the F terminal of the flame safeguard control sub-base or terminal strip, and the white wire to the G terminal.The flame can not be found by the UV detector with wrong connection.

Delivery terms and packaging

Packaging Detail: Packaged in cardboard boxes Delivery Detail: 1 week
Port: Tianjin

Payment term

Letter of credit

Telegraphic transfer

Фотографии

    Password recovery
    To recover your password, please enter in the box below your email address with which you have registered:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    An error has occurred. Please check your e-mail address and try again.
    Ваш новый пароль:

    Name is empty


    Выберите страну доставки

    You have not written a message

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    Your message has been sent!

    Close

    1
    Рынок B2B
    Cancel Close
      Show more close
        Area search
        Worldwide
        Категории
          Product