Boilers gas KSWO, OUTDOOR units, single and double, hot water boilers, water tube, gidrologo type, single-loop, heat-insulated block-box.
Boiler KSVA has a single or double heat exchanger, one or two open furnace equipped with one or two atmospheric gas burners. Boiler heat exchangers are made of finned tubes and belong to the class hydronic boilers (water velocity in pipes up to 2 m/sec).
The boiler can run on network gas and liquefied gas fuel. The boiler is equipped with timosaponin valve, gas alarm for methane and the gas shut off valve. The boiler is equipped with one circulation pump. In the event of a failure of the primary pump is also delivered backup pump.
The boiler belongs to low-temperature devices operating in the heating transactions closed type with forced circulation of coolant, are protected under binding rules. Can also work in heating the transactions of the open type with forced circulation of coolant, are protected under binding rules. The boiler is working in automatic mode with minimized maintenance. The device is equipped with systems protecting against failures in heating wiring:
a system of tracking the flow of coolant
inner temperature controller,
thermal switch
the safety valve.
The boiler is installed circulating pump, thermomanometer, automatic air release valve, safety overflow valve, naprmer, the indicator on the methane shut-off valve, terminatory valve, electric contact pressure gauge, GSM modem.
The equipment is subject to assessment (confirmation) of conformity to requirements of Technical regulations of the Customs Union TR CU 016/2013, which is carried out by certification and Declaration according to the diagrams in the regulation.
Requirements of reliability: mean time to failure - 23000 h; average life to retirement - 10 years.
Compliance of basic materials (sheet steel, pipe, rolling, forging, etc.) on the chemical composition and mechanical properties of NTD is confirmed by the quality certificate of the supplier of the material. Compliance of welding consumables standards and NTD is confirmed by the quality certificate and certificate of evaluation material in accordance with the requirements of RD 03-613. Dimensions of parts obtained by machining, in the absence of other requirements in the drawings have General tolerances according to GOST 30893.1: H14, h14, ±14/2 IT. The sizes of the diameters defining the sealing surface of type "protrusion-depression", "thorn-groove" performed for hole sizes – H12, shaft – h12. When butt-welding the offset edges along the outside diameter does not exceed 30% of the thickness of thin parts, but not more than 5 mm.
The cost of boilers from 273200р. The production time is 30 days.