Place of Origin |
Zhejiang China (Mainland) |
Brand Name |
IGERCN |
Model Number |
BK |
Usage |
Potential |
Phase |
Single |
Coil Structure |
Toroidal |
Coil Number |
Autotransformer |
Single phase BK control transformer The usual input voltage of single phase BK control transformer is 0V,220V,380V,460V,output voltage is 0V,6.3V,12V,24V,36V,etc.The mode of coneection can use lead wire,terminal and brass screw.BK control transformer is dry type transformer,suitable for the AC circuits of 50-60Hz,and are widely applied to all kinds of control circuit,sall motor of machinery and equipment,etc.Basic Data: Input Voltage: 0V,220V,380V,460V Output Voltage: 0V,6.3V,12V,24V,36V Power: 50VA-1.2KVA Frequency:50-60Hz Isolation Class:E Ambient temp: -25 degree celcius to +55 degree celcius Efficient≥90% Type of cooling system: natural air drying,dry type Winding conductor material:usual use copper,can use aluminum if you have special requirements Standard:VDEO550\IEC204-1\IEC439\JB5555\GB5226Appliance of BK control transformer BK series control transformers are widely applied to all kinds of CNC machinery,machinery equipment,control circuit, spot lighting,signal lamp,safe-light,small motor of machinery and equipmen and electric automatization,etc.Features of BK control transformer: Our BK control transformers are mede of optimal design and advanced technology,they are high efficient,low power loss,small size,safety cinnection, no wave distortion,widely used and easy to install ,maintenance.Also can support over load instant,work continuous for long time.Operating environment 1)Temp.:The ambient temperature can not over +40 degree celcius. 2)Altitude: Mounting location can not exceed the altitude of 2000m 3)Relative humidity: Maximum 90% 4)The site not attack by rain and snow 5)The medium which no explosion danger, no corroding metal, no electrical breakdownTesting Items: No-load Test(No-load Current, No-load Voltage, No-load Loss) Load Test (Load Voltage, Temperature-rise) Inductive Voltage Test DC Resistance Test Safety TestCertificate The certificate of our transformer has CE CQC RoHs ULNote: The above-mentioned single phase isolation and auto transformer are frequently-used, we can also manufacture the products by customer design. And the specification is for reference, if has the change further, please take the material object as the standard.Model Power(VA)Out size (mm)Install size(mm)Install hole(mm)ABCDEFBK-505077657263.5514BK-10010087817972644.9BK-15015097908580714.9BK-20020097958580764.9BK-30030011510810295824.9BK-40040011511810295914.9BK-500500135121117111885.8BK-600600135126117111935.8BK-8008001351361171111035.8BK-1K10001541641381271295.9BK-1.2K12001541841381271495.9