automatic transfer switch

automatic transfer switch

original price: 105,00 USD
Wenzhou, China
Production capacity:
5000000 Piece / Year
Wenzhou, China
Anonymous
86-577-62873876
Austin Zhao
Contact person

Basic Information

Place of Origin Zhejiang China (Mainland)
Brand Name HUYU
Model Number HUSD2
Type Moulded Case
Poles Number 4
Application: It is applied in the duplicate power supply system of AC 50Hz,rated gevolta is single phase 230V or three phases four wires 400V,rated current up to 800A.It can also be used in the unattended distribution room,to realize the automatic transfer between two power supplies . When there is any fault with one line of power supply, the device will automatically transfer to the other line within several seconds,which ensures the timely power supply of important locations(residential area,hospital,shopping center, and etc.). It accords with IEC60947-6-1 standard. FUNCTION: 1. According to each phase voltage value of two lines of power supply,itcan control the automatic transfer of two circuit breakers.The controller tests each phase voltage value of two lines of power supply. When the voltage is lower 80% of rated voltage,it is regarded as under-voltage .The circuit will judge the testing result and then deal with it.After set delay, the controller will issue a directive to the electrical ope-ration mechanism to make the two circuit breakers transfer. 2. Display function The left side circuit breaker (Q1) connects to normal power supply(N),and the right side circuit breaker (Q2) connects to reserve power supply(R), if each phase voltage of two lines of power supply is normal ,the controller will display NA,NB,NC,RA,RB,and RC.If any phase voltage is lower than 80% of rated voltage ,this phase will not be displayed and then the user can find out the power supply fault easily. 3. Setting function The users can set the delay time of automatic transfer of two lines of power supply according to their own needs , and the time range is from 0s to 30s.Control function can be chosen between Type R and Type S. 4. The two circuit breakers have electric and mechanical interlocking functions, which ensure the two circuit breakers cannot close at the same time. 5. Alarming function 5.1 If one line of power supply is abnormal ,during the transfer period between the two circuit breakers, the controller will alarm.After transfer, the alarm will stop. 5.2 Under normal running ,when the circuit breaker Q1or Q2 trips due to overload short-circuit ,the controller will alarm .Push the CO-BREAKING button on the controller ,the alarm will stop ,and then the tirpped circuit breaker will trip again.

Delivery terms and packaging

Packaging Detail: standard export carton Delivery Detail: 15-30days
Port: shanghai or ningbo

Payment term

Letter of credit

Telegraphic transfer

Western Union

Фотографии

    Password recovery
    To recover your password, please enter in the box below your email address with which you have registered:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    An error has occurred. Please check your e-mail address and try again.
    Ваш новый пароль:

    Name is empty


    Выберите страну доставки

    You have not written a message

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    Your message has been sent!

    Close

    1
    Рынок B2B
    Cancel Close
      Show more close
        Area search
        Worldwide
        Категории
          Product