Place of Origin |
China (Mainland) |
Brand Name |
JANOEL |
Model Number |
JN8-48 |
automatic egg incubator JN8-48,48pcs egg newest family incubator. 1pcs/colout carton,2 colour carton/big carton, packing size is 52x60x53/15kgs/2set. Push-button Instruction: AFTER OPERATED MACHINE,IT MAYBE GIVE AN ALARM, SO PLEASE PUT ANY KEY OF " SET", "+" OR " "-" TO WHITE ALERT. SET:A: Push SET once to enter temperature control set, push “+” or “-” to adjust parameter, push “+” or “-” for 3s to enter fast adjustment mode, push SET again to exit from setting state. B: Push SET for 3s to enter system menu set, push “+”or “-” to select menu in need of adjustment, then push SET again to enter relative parameter setting state, push “+” or “-” to select parameter in need of modification, push RST to exit after adjustment, or the system will exits after 5s delay. “+”: Up button“-”: Down buttonOperation Instruction: Indicating lamp state instruction:WORK lamp on the left side of display screen is made as work indicating lamp, LED normally on means it’s in heating state.SET lamp on the left side of display screen is used for indicating lamp set, LED normally on means it’s in setting state.Function instruction:HU, HD:Parameter HU and HD, set by factory, is supposed not to be modified by user.Temperature correction function:When measuring temperature deviates from reference temperature, temperature correction function shall be used to make the measuring value in accordance with reference temperature, temperature after correction shall be the sum of temperature before correction and correction value (correction value can be positive number, negative number or zero).Temperature correction set:Push “SET” for 3s to enter menu display, push “+” or “-” until code “CA” appears on screen, then push “SET” to display temperature correction setting value, push “+” or “-” again to adjust parameter.Upper and lower limit function:HS and LS set limits setting range of temperature control, e.g., if HS is set as +15 and LS is set as -10, then the temperature can only be set from -10 to +15, so the display value still keeps as -10 after pushing “-” if it displays -10; the display value still keeps as +15 after pushing ““+”” if it displays +15. If setting value is beyond the setting range, then HS and LS must be changed at firstUpper and lower limit set:Push “SET” for 3s to enter menu display, push “+” or “-” until code “HS” or “LS” appears on screen, push “SET” to display upper or lower limit setting value, then push “+” or “-” to adjust the parameter. HS means upper limit and LS means lower limit.Humidity alarm function:If measuring humidity is less than AU setting value, the temperature controller sends alarm and the humidity indicating lamp flickers. The alarm can stop by pushing any button.Humidity alarm set:Push “SET” for 3s to enter menu display, push “+” or “-” until code “AS” appears on screen, push “SET” to display humidity alarm setting value, then push “+” or “-” again to adjust parameter.High temperature alarm function:If measuring temperature is higher than sum of setting temperature and AH, the temperature controller sends alarm and the display screen alternately displays H and current temperature. The alarm can stop by pushing any button.High temperature alarm set:Push “SET” for 3s to enter menu display, push “+” or “-” until code “AH” appears on screen, push “SET” to display high temperature alarm setting value, then push “+” or “-” to adjust parameter, the high temperature alarm function can be closed when AH is set as 0.Low temperature alarm function:If measuring temperature is lower than the result when setting temperature minus AL, the temperature controller sends alarm and the display screen alternately displays L and current temperature. The alarm can stop by pushing any button.Low temperature alarm set:Push “SET” for 3s to enter menu display, push “+” or “-” until code “AL” appears on screen, push “SET” to display low temperature alarm setting value, then push“+” to adjust parameter. The low temperature alarm function can be closed when AL is set as 0.Menu Code SelectionSymbolInstructionSetting rangeFactory setUnitHUHeating power parameter1-9018HDHeat preservation power parameter1-8011LSSetting lower limit-9.9 HS30°CHSSetting upper limitLS 99.939.5°CCATemperature correction-5 +50°CASHumidity alarm1 9945%AHUltrahigh temperature alarm output0-151°CALUltralow temperature alarm output0-151°C