Atomic Absorption Spectrophotometer

Atomic Absorption Spectrophotometer

Hangzhou, China
Hangzhou, China
Company
86-571-88228269
Jessie Shao
Contact person

Basic Information

Place of Origin Zhejiang China (Mainland)
Brand Name CH
Model Number 3500 Series
Atomic Absorption Spectrophotometer SP-3500 Seriesis a new generation of domestic high level products that it broke the technology bottleneck of D-lamp background correction. And also provided a reliable safeguard for elements quantitative analysis CharacterUnique full reflection optical systemD-lamp background correctionHigh resolution and exact peak seeking ability3 Atomic temperature rise modeUnique design automatic 8 lamps holder systemSteady flow full titanium burnerIntelligence control functionGeneral safety precautionsWindow2000/XP conciseness, professional, automatic, full operation SP Win-AAS softwareQA/QC functionFull information measurement Products TypeSP-3520AA (FLAME)SP-3530AA(Enhancement type)SP-3500GA(Graphite furnace power supply)SP-3530GA(Graphite furnace power supply)SP-3500AA SP-3520AA (FLAME) SP-3530AA(Enhancement type) SP-3500GA(Graphite furnace power supply) SP-3530GA(Graphite furnace power supply)Model SP-3520AA SP-3530AAMain Parameter Optical System Instrument Type Single Beam Reflection Achromatic Optics SystemMonochrometer: Achromatic C-TBandwidth(nm):0.1,0.2,0.7,1.4nm AdjustableWavelength Range(nm):190-900Wavelength Accuracy(nm):±0.20Wavelength Repeatability(nm):≤0.10Resolution better than 0.3nm(Mn279.5nm and 279.8nm peak valley≤30%)Spectrophotometric Properties Measurement: A.T.CPhotometric Range:0-125%,-0.1-3.00AStatic Baseline Drift(Cu):±0.003A/30minDynamic Baseline Drift(Cu):±0.004A/30minBackground Correction: D-lamp background correction,Self-absorbance background correction >50times correction ability(1Abs)Atomization System: Flame + graphite furnaceFlame Characteristic Concentration:(Cu)≤0.03ug/mL/1%Detection limit:(Cu)≤0.006ug/mLPrecision:RSD≤1%Burner:titaniumNebulizer:hight-efficient glass nebulizerSpray chamber:anticorrosion materialSafety measures:Flame fuel gas, power assisted gas abnormal pressure protectionGraphite FurnaceCharacteristic quantity Characteristic value: Cd≤0.5×10-12gDetection Limit Characteristic value: Cd≤1.0×10-12gPrecision Precision: Cd≤3%Test Manner :Flame, Graphite Furnace, hydride-AA, flame emissionData ProcessConcentration:Standard curve, standard addition, interpolationTimes of repetitive Measurement:1-30times,Average value of A&CQA/QC:relative coefficient,Abs. concentration SD,RSD,Analysis data electronic document export is feasible.data output:Test data could be saved as original record form through Pro-softwarereport print:parameters, data result, graphdata interface:Standard RS-232 interfaceInstrument function Instrument setup D-lamp background correction auto-adjust optics beam deviceAutomatic wavelength scan, peak seeking band width adjustAutomatic ignite adjust negative high voltagelamp current, balance two beams, flameout protection

Delivery terms and packaging

Port: Shanghai

Payment term

Letter of credit

Telegraphic transfer

Фотографии

    Password recovery
    To recover your password, please enter in the box below your email address with which you have registered:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    An error has occurred. Please check your e-mail address and try again.
    Ваш новый пароль:

    Name is empty


    Выберите страну доставки

    You have not written a message

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    Your message has been sent!

    Close

    1
    Рынок B2B
    Cancel Close
      Show more close
        Area search
        Worldwide
        Категории
          Product