Display Type |
Analog Only |
Phase |
Single Phase |
Place of Origin |
Zhejiang China (Mainland) |
Brand Name |
Holley |
Model Number |
HLD06) |
Measuring Energy Range |
120~240V |
Accuracy Class |
Class 100 |
Output Voltage |
120V~240V |
Operating Temperature |
-30~70 |
Dimensions |
175x175x130mm |
1. General The hld06 single-phase meter is a socket type meter designed to meet the latest ANSI C 12.1 and ANSI C 12.10 standards. The meter measures active energy in single-phase two wire or three wire alternating current power grids. Connection is fm 1s and fm 2s. It is a reliable long service life meter. The average service life (mttf) is 30 years and the maximum current is 200a. Both cyclometer-type and pointer registers are available. In addition, it can be equipped with an amr module. 2. Construction 2. 1 meter case The socket type meter case complies with ANSI C 12.7-1993 and meets the protection requirements set by ANSI C 12.10-1993. 2. 2 driving element The driving element consists of a voltage element and a current element, both of which are fixed on the aluminum alloy frame. It has a load curve compensation mechanism and an inductive load adjustment mechanism. 2. 3 rotor The worm is an un-detachable part of the shaft so that the mesh between the worm and shaft is improved. Both ends of the shaft are embedded with graphite bearing to ensure the long service life of the meter. 2. 4 upper bearing The upper bearing consists of a guide pin and an aluminum sleeve. 2. 5 lower bearing The lower bearing consists of a guide pin and a brass sleeve, and is fixed into the meter frame by one screw. 2. 6 braking element Two magnet cubes are die-casted into the meter frame by aluminum alloy. It has a temperature compensation plate. 2. 7 frame The frame is die-casted by high quality sial alloy of stable property to avoid distortion. It has a low load adjustment mechanism. 2. 8 register Both pointer and cyclometer registers are available. 3. Technical data Meter type: Hld06 Applicable standards: ANSI C 12.1 and ANSI C 12.10 Class: 10 \ 20 \ 100 \ 200 Test current ib: (a) 2.5 \ 2.5 \ 15 \ 30 Meter constant: (r/kwh) 1400 \ 1200 \ 360 \ 90 Average service life (mttf): 30 years Overload capacity %ib 667 Heat capacity: Ib+imax Short time over current: 7000a short circuit 0.1s Reference voltage un v 110v, 120v, 220v, 230v, 240v, 277v, and 480v Reference frequency: 60hz Non-running with no-load: 0.9 1.1un Starting current: 1%ib Rated load speed at ib: 11 r/min Power losses in voltage circuit at 60hz un <1w/5va Power losses in current circuit at ib <0.5va A. C. Voltage test at 60hz, 1min, 2.5kv Impulse voltage test 1.2/50ms >6.5kv Rated load torque at unity pf, ib 400u n. M Weight of rotor: 26 g Weight of meter: Approximately 1.7kg Main case: bakelite base/glass cover Registerpointer or cyclometer type Option reverse running stopper, pulse sampling device