acsr conductor

acsr conductor

original price: 1,00 USD
China
Production capacity:
300 Kilometer / Day
China
Company
86-371-69382266
Edward Lee
Contact person

Basic Information

Place of Origin Henan China (Mainland)
Brand Name jiapu
Insulation Material Other
Application Overhead
1. ApplicationsConductor(AAC and ACSR) have been widely used in power transmission lines with various voltage levels, because they have such good characteristics as simple structure, convenient installation and maintenance, low cost large transmission capacity. And they are also suitable for laying across rivers valleys and the places where special geographical features exist.2. Service Performance(1). The permissible long-time operating temperature for aerial conductor is 70oC.(2). Under the circumstance that rare climate is occuring and ice coverage rate low in heavy ice area, the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.(3). When connecting conductors, the conductor beside the connecting tube cant be prominent. Otherwise, the force on the operating conductors will be unbalanced. After connectors are install, the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.(4). Under installaion, the arc downing stress of all the conductors should be the same. With in the permissible distance of crossing buildings or dropping to the ground, the stress can be 10-15% higher than regular stress.3. Product Performance(1). The electrical performance of AAC and ACSR is indicated in DCΩ/km(20oC). The resistivity of the hard aluminum wire for stranded wires is not greater than 28.264 nΩ. m of international standard value.(2). The rated tensile strength of AAC is denoted with the result of total cross-section of all aluminum conductors multiplied by min. tensile of corresponding size specified in the standard for aluminum wire.(3). The rated tensile strengh of ACSR is denoted with sum of all aluminum conductorstensile strength and steels tensile strength.a. The tensile strength of all aluminum conductors is denoted with the result of all cross-sections of aluminum conductors multiplied by min. tensile strength of corresponding size specified in the standard for aluminum wire.b. The tensile strength of all steel wire is denoted with the result of all cross-sections of steel wires multiplied by the stress at 1% elongation of corresponding size specified in the standard for steel wire.4. Material Standard(1). The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997(equivalent to IEC 60889: 1987).(2). The zinc coated steel wire used for ACSR conforms to IEC 60888: 1987.(3). Production can be arranged according to customers requirements for material standard, etc.Construction of All Aluminum Conductor and Aluminum Conductor Steel Reinforced

Delivery terms and packaging

Packaging Detail: export wooden drums Delivery Detail: without 11 days after S/C
Port: Qingdao or other port of China

Payment term

Documents Against Payment

Letter of credit

Telegraphic transfer

Western Union

Фотографии

    Password recovery
    To recover your password, please enter in the box below your email address with which you have registered:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    An error has occurred. Please check your e-mail address and try again.
    Ваш новый пароль:

    Name is empty


    Выберите страну доставки

    You have not written a message

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    Your message has been sent!

    Close

    1
    Рынок B2B
    Cancel Close
      Show more close
        Area search
        Worldwide
        Категории
          Product