ABB Pressure Transmitter 2600T series

ABB Pressure Transmitter 2600T series

Shanghai, China
Production capacity:
1000 Set / Month
Shanghai, China
Beginner
86-21-58754297
Zhuang Chris
Contact person

Basic Information

Place of Origin United States
Brand Name ABB
Model Number 2600T series
Base accuracy : ±0.04% *Span limits – 0.2 to 60000kPa; 0.8inH2O to 8700psi – 0.3 to 3000kPa abs; 2.25mmHg to 435psia * Reliable sensing system coupled with very latest digital technologies – provides large turn down ratio up to 100:1 * Comprehensive sensor choice – optimize in-use total performance and stability * 5–year stability * Flexible configuration facilities – provided locally via local keys combined with LCD indicator or via hand held terminal or PC configuration platform *Multiple protocol availability – provides integration with HART®, PROFIBUS PA and FOUNDATION Fieldbus platforms offering interchangeability and transmitter upgrade capabilities * Full compliance with PED Category III Data Sheet SS/265GS/AS_4 ABB 2600T Series Engineered solutions for all applications Base accuracy : ±0.04% *Span limits – 0.2 to 60000kPa; 0.8inH2O to 8700psi – 0.3 to 3000kPa abs; 2.25mmHg to 435psia *Reliable sensing system coupled with very latest digital technologies – provides large turn down ratio up to 100:1 * Comprehensive sensor choice – optimize in-use total performance and stability *5–year stability *Flexible configuration facilities – provided locally via local keys combined with LCD indicator or via hand held terminal or PC configuration platform * Multiple protocol availability – provides integration with HART®, PROFIBUS PA and FOUNDATION Fieldbus platforms offering interchangeability and transmitter upgrade capabilities * Full compliance with PED Category III FieldIT 2600T Series Pressure Transmitters Model 265GS Gauge Model 265AS Absolute standard overload 2600T Pressure Transmitters Model 265GS, 265AS SS/265GS/AS_4 2 Operative limits Temperature limits °C (°F) : Ambient (is the operating temperature) Silicone oil filling: –40°C and +85°C (-40°F and +185°F) Inert filling: –20°C and +85°C (–4°F and +185°F) White oil filling: –6°C and +85°C (+21°F and +185°F) Lower limit for Viton gasket: –20°C (–4°F) Lower limit for perfluoroelastomer gasket: –15°C (+5°F), –25 resp.–15°C (–13°F resp.+5°F) - (see section Pressure limits) Upper limit for perfluoroelastomer gasket: +80°C (+176°F) Note : For Hazardous Atmosphere applications see the temperature range specified on the certificate/approval relevant to the aimed type of protection. Process Lower limit – –50°C (–58°F); –20°C (–4°F) for Viton gasket. –6°C (+21°F) with white oil filling –25 resp.–15°C (–13°F resp.+5°F) for perfluorelastomer gasket - (see section Pressure limits) Upper limit – Silicone oil, inert fluid and white oil: 120°C (250°F) – Perfluorelastomer gasket: +80°C (+176°F) Storage Lower limit: –50°C (–58°F); –40°C (–40°F) for LCD indicators –6°C (+21°F) with white oil filling Upper limit: +85°C (+185°F) Pressure limits Overpressure limits (without damage to the transmitter) 0 absolute to – 1MPa, 10bar, 145psi for sensor codes C, F – 0.5MPa, 5bar, 72.5psi for sensor code L – 2MPa, 20bar, 290psi for sensor code D – 6MPa, 60bar, 870psi for sensor code U – 20MPa, 200bar, 2900psi for sensor code R – 90MPa, 900bar, 13050psi for sensor code V – 0.18MPa abs, 1.8bar abs, 26psia for perfluorelastomer gasket, Temp ≥ –25°C (–13°F) Proof pressure The transmitter can be exposed without leaking to line pressure of up to – 1MPa, 10bar, 145psi for sensor codes C, F – 0.5MPa, 5bar, 72.5psi for sensor code L – 2MPa, 20bar, 290psi for sensor code D – 6MPa, 60bar, 870psi for sensor code U – 20MPa, 200bar, 2900psi for sensor code R – 90MPa, 900bar, 13050psi for sensor code V – 0.18MPa abs, 1.8bar abs, 26psia for perfluorelastomer gasket, Temp ≥ –25°C (–13°F) Note : Lower Range Limit (LRL) for 265AS is 0 abs for all ranges. Span limits Maximum span = URL IT IS RECOMMENDED TO SELECT THE TRANSMITTER SENSOR CODE PROVIDING THE TURNDOWN VALUE AS LOWEST AS POSSIBLE TO OPTIMIZE PERFORMANCE CHARACTERISTICS. Zero suppression and elevation Zero and span can be adjusted to any value within the range limits detailed in the table as long as: – calibrated span ≥ minimum span Damping Adjustable time constant : 0 to 60s. For ordering, please feel free to contact: chris.zhuang @ reyo-sh. com. cn; chris_zla @ yahoo. com. cn

Delivery terms and packaging

Packaging Detail: Regular export cargo container and package up to client's request. Delivery Detail: 30 Days shipped to destination upon order
Port: Shanghai (or other southern China port up to client's preference)

Payment term

Telegraphic transfer

Western Union

Фотографии

    Password recovery
    To recover your password, please enter in the box below your email address with which you have registered:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    An error has occurred. Please check your e-mail address and try again.
    Ваш новый пароль:

    Name is empty


    Выберите страну доставки

    You have not written a message

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    Your message has been sent!

    Close

    1
    Рынок B2B
    Cancel Close
      Show more close
        Area search
        Worldwide
        Категории
          Product