Transformer (1)Transformer (2)CT (3)Low Voltage Current Transforme
Transformer (1)Transformer (2)CT (3)Low Voltage Current Transforme
Transformer (1)Transformer (2)CT (3)Low Voltage Current Transforme
Transformer (1)Transformer (2)CT (3)Low Voltage Current Transforme
Transformer (1)Transformer (2)CT (3)Low Voltage Current Transforme
Transformer (1)Transformer (2)CT (3)Low Voltage Current Transforme
Transformer (1)Transformer (2)CT (3)Low Voltage Current Transforme
Electronic Transformer This product uses the unique transistor protection line,special crystal lization alloy magnetism Material,enough power,remainder,good luminosity,the
70W Max. Power Transformers Power Transformers Model: YT70 series Rated Power:70W max. Input: 220-240V AC or 100-120V AC 50/60Hz Output Voltage: 5-36V Dimension: 76*40mm Dimensi
CURRENT TRANSFORMER CURRENT TRANSFORME
POWER TRANSFORMER POWER TRANSFORME
TRANSFORMER Main characteristics
CURRENT TRANSFORMER Main characteristic
CURRENT TRANSFORMER CURRENT TRANSFORME
Transformer Transformer Circumstance temp 0--+40 degree Appearance &dimension: as image Terminal distance: 4 pins Appearance size: 15.5*15.5 mm Terminal leng
transformer
High voltage transformer We produce transformers for electronic insecty killers,neon signs,oil/gas burner.Ozone generator,air purifier,anti-static products and so on. we can
YD series light test transformer
YDQ inflatable high voltage test transformer
VOLTAGE Transformer Main functions and features (USED FOR MF INDUCITON FURNACE) They are widely used in electrolysis, electrochemical, driving, traction,static de-dustin
Transformer Main functions and features They are widely used in electrolysis, electrochemical, driving, traction,static de-dusting,DC power transmission fields w
Furnace Transformer The detailed discription of our rectifier transformer: Main Function and Features: They are widely used in electrolysis, electrochemical, driving, t
S9-M S10-M S11-M S11-MR Series Full-sealed Distrib S9-M S10-M S11-M S11-MR Series Full-sealed Distribution Transformer Introduction To Products The performance of model S9-M,S10-M,S11-M,S11-MR 10KVse
220KV Transformer transformer Main functions and features (USED FOR MF INDUCITON FURNACE) They are widely used in electrolysis, electrochemical, driving, traction,stat
Transformer, hvac part Foot Mount, 50/60HZ Dielectric strength-3500VRMS hipot UL Class II, Class B insulation system, Heavy duty with circuit breaker PART NO.VA RATINGPRIMA
110kV Single-phase SF6 Capacitor Voltage Transfor Technical Parameters for TYDL 110/√3 - 0.01H SF6 Capacitor Voltage Transformers 1 Rated voltage 110/√3kV 2 Highest voltage for equipment
10kV Indoor Single-phase Post Type Epoxy Resin Ins Technical data for ZNZ-10 insulators 1Rated Insulation Level: 12/42/75kV 2 Contrast of type and drawing No. see Table1. Table 1 Contrast of Type and
110kV Single-phase SF6 Inductive Voltage Transform Technical Parameters for JDQXF-110W (1 3) Voltage Transformers 1 Rated voltage 110/√3 kV 2 Highest voltage for equipment 126 kV 3 Rated freque
220kV SF6 Current Transformers Technical Parameters for LVQB3-220W(1 3) Current Transformers 1 Rated voltage 220 kV 2 Highest voltage for equipment 252 kV 3 Rated primary current 3
10kV Indoor Epoxy Resin Current Transformers Technical Parameters forLZZBJ10-10(A C) Current TransformersTechnical Parameters TableRated Primary Current In(A)Accuracy ClassRated Output at Relati
10kV Indoor Epoxy Resin Current Transformers Technical Parameters forLDJ8 - 10Q Current Transformers Technical Parameters TableRated Primary Current In(A)Accuracy ClassRated Output at Relative A
Transformer for Control Circuit 1 Instruction for YDZW-10Transformers for Control CircuitThe product is a special transformer for power supply of the operating mechanism for a circu
(10 35)kV 3-Phase Dry-type Power Transformers 1The products are especially suitable for installation in draw-out type or fixing type switchgears as well as for power plants or substation self-con
10kV Indoor Epoxy Resin Current Transformers Technical Parameters for LZZBJ9-12/175b/4 Current TransformersTechnical Parameters TableRated Primary Current In(A)Accuracy ClassRated Output at Rela
40.5-420kV Single-phase (3-phase) Porcelain Insula 1Instruction for LMWSB Insulators Matching for HV Switchgears The single-phase or 3-phase insulators are matching 40.5 kV, 72.5 kV, 126 kV, 145 kV, 1
10kV Indoor Epoxy Resin Voltage Transformers 1.The technical data and electric performance for the product all are the same as that of JDZ8-6(10) and JDZF8-6(10) VTs, but the terminals are marke
0.66kV Indoor Busbar Going-thru Type Epoxy Resin C Technical Parameters forLMZC5-0.66/Φ100(Φ120)Current Transformers Technical Parameters TablePrimary Residual Current(A)Rated Secondary Curren
Indoor Voltage Transformers Technical Parameters for JDZ(F)X13-35GY Voltage Transforners Technical Parameters TableModelRated Voltahe Ratio (kV)Accuracy ClassRated Output (VA)Li
24kV Indoor Single-phase Busbar Wall Going-thru T Technical data for CMJ-24Q bushings: 1. Rated voltage : 24kV; 2.Rated Insulation Level: 24/65/125kV; 3. Creepage distance: not less than 480mm; 3. Q:
150kV Single-phase SF6 Voltage Transformers 1 Instruction for JDQXF2-150ZHW Voltage Transformers The single-phase voltage transformers are matching GIS or PASS high voltage switchgears. Their d
10kV Hermetic Oil-immersed Distribution Transforme Standards GB1094.1 2-1996 GB1094.3,.5-2003 GB/T6451-1999 Service conditions 1) Altitude: ≤1, 000m 2)Maximal ambient temperature: +40.C 3)Maximal
3-Phase Dry-Type Distribution Transformer Standard GB/T1094-1996 GB/T10228-1997 GB6450-1986 GB4208-1993 Service condition 1)Altitude:≤1, 000m 2)Highest ambient temperature:+40'C 3)Highes
35kV Hermetic Oil-immersed Distribution Transforme Standards GB1094.1 2-1996 GB1094.3,.5-2003 GB/T6451-1999 Service conditions 1) Altitude: ≤1, 000m 2)Maximal ambient temperature: +40.C 3)Maximal
10kV Three Phase Oil-immersed Power Transformer Standards GB1094.1 2-1996 GB1094.3,.5-2003 GB/T6451-1999 Service conditions 1) Altitude: ≤1, 000m 2)Maximal ambient temperature: +40.C 3)Maximal
Furnace Transformer •Main function and features An electric furnace transformer is used to supply power to an electric furnace , which lowers the high voltage to t
220kv 110kv and 66kv Low-loss series Power Transfo •General EACHER brand 220kv 110kv and 66kv low-loss series transformer is our independently developed new generation of transformers on the bas
SC(B) Type Cast-resin Dry-type Transformer •Application Of Products Our SC(B) series epoxy resin cast dry transformer is cast under vacuum with thin insulating bands automatically . The
Rectifier Transformer •Main function and features They are widely used in electrolysis, electrochemical , driving, traction , static de-dusting ,DC power transmissio
ZGS pad- mounted transformer •Main function and features Small volume, compact structure, reliable power supply and easy for installation; it can realize single power suppl
YB Series Cubicle-type Substation Transformer •Main function and Features The product consists of HV distribution unit, and LV distribution unit and is divided into HV chamber, transformer