pad mounted transformer components bay-o-net for pad mounted transfomer components, With the broadest array of transformer components for ANSI/IEEE design type equipment, Cooper supplies transfo
pad mounted transformer components two positions l With the broadest array of transformer components for ANSI/IEEE design type equipment, Cooper supplies transformer and switchgear OEM's with the reli
EI ferrite core TYPEDimensions(mm)C1AeLeVeAL(nH/N2)±25% weightABCDEminFImm-1mm2mmmm33.5KXP3XP4EI12.512.5±0.37.4±0.25.0±0.22.4±0.29
EE ferrite core TYPEDimensions(mm)C1AeLeVeAL(nH/N2)±25%weightEE55.25±0.12.65±0.081.95±0.11.35±0.13.82.0±0.084.72.6612.533.3
PQ Ferrite core TYPEDimensions(mm)C1AeLeVeAL(nH/N2)±25%weightABCDEFGminmm-1mm2mmmm3XKXP3XP4PQ20/1620.5±0.418.0±0.48.8±0.214.0±0.45
T Ferrite core
EER ferrite core TYPEDimensions(mm)C1AeLeVeAL(nH/N2)±25%weightEC4242.0±0.822.4±0.315.1±0.315.1±0.330.015.4±0.30.5189.197.018
EER ferrite core TYPEDimensions(mm)C1AeLeVeAL(nH/N2)±25%weightABCDEminFmm-1mm2mmmm3XKXP3XP4EC28/2828.5±0.614.0±0.311.4±0.39.9±0.321
EFD ferrite core TYPE Dimensions(mm)C1AeLeVeAL(nH/N2)±25%weightABCDEFGmm-1mm2mmmm3XKXP3XP4EFD1212.5±0.36.2±0.13.5±0.15.4±0.159.0&pl
EPC ferrite core TYPE Dimensions(mm)C1AeLeVeAL(nH/N2)±25%(g) weightABminC1C2DEminFHmm-1mm2mmmm3XKXP3XP4EPC1010.2±0.27.65.0±0.11.9±0.14.05&
EP ferrite core TYPEDimensions(mm)C1AeLeVeAL(nH/N2)±25%weightABCDEFmm-1mm2mmmm3XKXP3XP4EP56.0±0.152.8±0.051.7±0.13.8±0.14.4±
RM ferrite core TYPEDimensions(mm)C1AeLeVeAL(nH/N2)±25% weightABCDEFGminmm-1mm2mmmm3XKXP3XP4PQ20/1620.5±0.418.0±0.48.8±0.214.0±0.4
Transformer Main technical data
Dry Type Transformer Main Technical Data of try type transformer: 1.Rated capacity : 30 2500kVA 2.Rated HV :up to 15kv 3.High short-circuit resistant ability Low loss L
Cast Resin Transformer Cast ResinTransformer Technical Data
35kV Power Transformer Main Technical & Charateristic: The installation altitude of power thansformer should not be over 1000m Ambient Temperature should be between -40
Mining Transformer Main Technical Data & Characteristics: Mining transformer KS9 series ore transformer is applied to certain places with gas,but no explosion dange
Furnace Transformer Furnace smelting furnace transformer is a transformer industrial area, which is based on various operating characteristics and operational characteri
Dry-type transformer the series transformer are featured with large capacity, low loss, reasonable structure,stable output voltage and etc,. and are widely used in power
Epoxy resin dry-type power transformer 1. Safety, fire, pollution-free, direct operation and load center 2. HTT using the German technology, high mechanical strength, strong ability of ant
Rectifier Transformer Intermediate frequency electric furnace transformer with the rectifier load is characterized by intermediate frequency electric furnace designed for
Autotransformer Reactor capacity: According to the user motor voltage levels, power, current-matching Frequency: 50 (60) Hz Insulation class: F class Start current:
Dry-type transformers the series transformer are featured with large capacity, low loss, reasonable structure,stable output voltage and etc,. and are widely used in power
220kv power transformer 220kv power transformer:Feature: 220kv on-load-tap-changing power transformer is made of high-quality silicon-steel sheets,and laminated by steps,it
110kv power transformer 110kv power transformer General: The core of 110kv power transformer is high quality silicon steel,with several layeres lapped ,it is low loss,low n
S9-35kV Series oil immersed power transformer S9-35kV Series oil immersed power transformer General Adopting advanced and strictly technology, the 35kV transformer that we develops to produce ind
S9-M three phase oil immersed transformer S9-M three phase oil immersed transformer Application S9-M-30 1600kVA Three Phase Oil-immersed seald Transformer is used in 10kV,50Hz or 60HZ power
SH15-M Three phase Amorphous alloy transformer SH15-M Three phase Amorphous alloy transformer Its core is amorphous alloy , The amorphous alloy is with relatively high magnet induction intensity,l
Furnace Transformer Furnace Transformer Main Functions and Features An electric furnace transformer is used to supply power to an electric furnace, which lowers the high
Rectifier Transformer Rectifier Transformer Main Functions and Features They are widely used in electrolysis, electrochemical, driving, traction, static de-dusting, DC po
LZZBJ9-12 Current transformer LZZBJ9-12(LZZ9-12) Current TransformerLZZB9-12C(Q) General: LZZBJ9-12(LZZ9-12) Current Transformer is shaped with epoxide resin. Its structure is tot
SC(B)10 Series Three Phase Resin Insulation Dry Ty SC(B)10 SeriesThree Phase Resin Lnsulation Dry Type Power Transformer General SC(B)10 Three Phase Resin Lnsulation Dry ype Power Transformer is the n
JDZJ-10 Voltage transformer JDZJ-10 Voltage Transformer General: JDZ-10 Voltage Transformer which is shaped with epoxide resin is a kind of insulatedsemi-closedindoorsingle-phas
LZZBJ12-12 Current Transformer TypeLZZBJ12-12current transformer is used for metering and protective relaying purposes for installation in indoor up to 12kV rated voltage frequency
20kV Series Resin Insulating Dry-Type Transformer transformer 1. Rated high-voltage:20kV Connection group: Dyn11 or Yyno 2. Rated low-voltage:0.4kV Insulating level: L1 125AC 50/L1 0AC3 3. Tapping ra
Electrical power Transformer We provide the transformers with voltage of 35/6.3KV,66/6.3KV,110/6.3KV
660V Distribution current transformer Performance characteristics and application areas: 660VDistribution current transformer of good voltage seperation ability and insulation property wi
Oil-immersed /Dry power transformer 66KV 110KV 145KV 220KV Outdoor SF6 current transformer 1.our transformer accord with national stardard GB1208-1997(current transformer)and GB1207-199
split-core current transformer Split Core Current Transformer Frequency band : 50Hz 60Hz 1KHz MAX Dielectric strenght: 3000Vrms/
split core current sensor CLAMP-typeCURRENT sensor Performance characteristics and application areas: Small valume, low price , high linearity , clamp meter is designed to pro
66 220KV Outdoor SF6 Electromagnetic transformer 66KV 110KV 145KV 220KV Outdoor SF6 current transformer 1.our transformer accord with national stardard GB1208-1997(current transformer)and GB1207-199
assembled type hign power transformer assembled type hign power transformer 1.our transformer accord with national stardard GB1208-1997(current transformer)and GB1207-1997(voltage transfo
Outdoor dry power transformer Outdoor dry power transformer 1.our transformer accord with national stardard GB1208-1997(current transformer)and GB1207-1997(voltage transformer) RE
split core current sensor Clamp-type current sensor Performance characteristics and application areas: Small valume, low price , high linearity , clamp meter is designed to pr
Precision micro current transformer CURRENT TRANSFORMER Preformance characteristics: Good volitage seperation ability and insulation property, the insulation resistance: 100MΩ/mi
Current transformer with DC-Immune Performance characteristics and application areas: current transformer with DC immune ,Epoxy resin molding encapsulation, good mechanical property a
Electric meter current transformer Preformance characteristics and application areas: current transformer,Epoxy resin molding encapsulation, good mechanical property and insulation pr
660V Distribution current transformer current transformer ,good voltage seperation ability and insulation property with 5A secondary output Meet IEC60044-1 standard The detailed specifica
Current transformer current transformer ,good voltage seperation ability and insulation property with 5A secondary output Meet IEC60044-1 standard The detailed specifica
Current transformer The current transformer is made of nanocrystalline alloy cores.High precision, small error received the warm welcome...