Solid State Relay single phase solid state relays(SSR) 1.Low price and high reliability 2.105 output capacitor 3.AC input power suitable for the world 4.High efficien
ZYS11 (RE11 RM MW) TIMER RELAY ZYS11 (RE11 RM MW) TimerRelayis used widely in various areas where needs high-precision, high reliability, automation control by time relay. Features
ZYS48M LED Display Time Relay ZYS48M Time Relay I. Brief Introduction A. Power delay: Contact the power supply, the product can start delay. When the delay time reaches the preset
ZYG-HD Solid State Relay Description reliable, fast switch, noiseless, long life, compact, no spark, corrosion resistant, explosion-proof, anti-vibration Specification Contro
ZYG-H3D Solid State Relay and SSR and Relay Specification Control Methods: ZYG-H3D DC-AC; ZYG-H3A AC-AC Load Current: 150A, 200A, 300A Load Voltage: 400VAC; 600VAC; 1200VAC Control Voltage: ZYG
LR2-D1310 thermal overload relay LR2-D13 thermal overload relay,relay Specification: The relay has different mechanism and temperature compensation and can be plugged in LC1-D series
Solid State Relay Solid State Relay Features: 1) Dimensions: 62 x 45 x 23mm 2) Load voltage: 24 - 380VAC 3) Max. load current: 25Ah 4) Input control: PWM signal 5) Am
SSR25 Solid State Variable Relay Solid State Variable Relay Features: 1) Dimensions: 57.5 x 44 x 22mm 2) Load voltage: 24 - 380VAC 3) Max. load current: 25A 4) Input control: 500K v
High DC switching capacity Electronic Relay High DC switching capacity Variety of applications Compact design Simple connection Clip fixing Contact type contact maker, normally open (Relay/MOSF
Single-phase AC SSR 10 to 120 Amps AC SSR Series SGDH are power line relays allowing 10 to 120 Amps. switching power, with Voltage ratings from 280 to 480 Volts A.C.SGD
Control Panel DIN Rail Control Panel DIN Rail Manufacturer: T&G Item: DIN Rail Model No.: T&G D357.5E10+ DIN Type: 35 mm standard din rail Cross Section Dimension:
THERMAL RELAY APPLICATIONS This series of thermal relay can be used in the circuit of 50Hz or 60Hz,rated insulation voltage660V,rated current 0.1-96A for protecti
GENERAL RELAY APPLICATIONS The following general relay is widely suitable for DC or AC circuit switching in various automation devices, process control and commmu
Solid State Relay We areone of the leading relay manufacturers in China.provide a wide variety of electrical components, including power relays, solid state relay, PCB
Relay border=0>
General Purpose Relays Relay parameter tableClassification General Purpose Relays Model JQX-15F(T90) Outline L*W*H(mm) 32.2*27*20.4 Feature Contact change-over capacity:30A
Digital time delay relay (JSS48A/DH48S) Digital time delay relay (JSS48A/DH48S)Features Specifications: Relay(timer relay,time switch relay
Time relay (Two way dial switch adjustable, ASY-3D Dial switch adjustable time relay (time count relay): Model number ASY-3D Contact form On-delayDPDT Delay range 0.1s-999min Power consumption 3W max
Solid State Relay (Single Phase AC SSR YHDA) Solid State Relay Single Phase AC-AC SSR YHDA: SSR series PCB typeModelSSR-YHD◊◊◊◊DAControl MethodsDC-ACLoad Current10A,15A,20A,25A,3
relay socket 1.Prompt Delivery 2.Quality Approvals,Easy operation 3.all Orders Accepted EN RELAY is widely suitable for DC or AC circuit switching in various auto
electronic relay EN RELAY is widely suitable for DC or AC circuit switching in various automation devices.process control and communication equipments etc.it has char
61F-G floatless relays Description Floatlessrelay Contactcapacity 5A,250VAC Ratedvoltage AC110V,220V,240V Operatingvoltage 85-110%oftheragedvoltage Operatingresistance 4K&O
TIMER MODELAH771AH710TB35TB35BCONTACT CAPATTYAC230V 16AAC230V 16AAC220V 10AAC220V 10AFULL TIMING RANGE24H24H24H24HCONTACT RESISTANCE≤50mΩ≤50m&O
thermal relay APPLICATION Thisseries new thermal relays are suitable in circuit of AC 50Hz voltage up to 660V and electric power under 45Kw for thermal overload pr
973 relay relay technical detail: outline dimension(mm):19.5×15.5×15contact form:1A,1B,1C rated load:10A 250VAC /15A125VAC/7A24VDCcoil voltage:3VDC
T90 relay relay 1)outline dimension(mm):32.2×27.6×27.6 2)contact form:1A,1B,1C 3)rated load:NC:20A 240VAC/28VDC NO:30A 240VAC/28VDC 4)coil voltage:
T74 relay relay: Parameters of the projectRelevant dataoutline dimension(mm)16×12.5×14contact form1A,1B,1CContact materialAgCdO,AgSnOrated load10A
14F relay relay: Size(mm):29*12.5*20.5 Rated Load:5A 250VAC 5A 28VDC Coil Voltage:3 24VDC Electrical Life:100000 Tim
T91 relay relay: Parameters of the projectRelevant dataoutline dimension(mm)32×27.6×27.6contact form1A,1B,1CContact materialAgCdO,AgSnOrated load20
922 relay relay 21F: Size(mm):20.3*16.5*20.5 Rated Load:15A 250VAC 15A 24VDC Coil Voltage:3 24VDC Electrical Life:100000 Tim
thermal relay Specification: typeRated working current of thermal relayThermal componentRated current(A)Rated or scale of rated current(A)FLR2-D1325FLR2-D13010.160
thermal relay Specification: typeRated working current of thermal relayThermal componentRated current(A)Rated or scale of rated current(A)FLR2-D1325FLR2-D13010.160
magnetic starter Specification: Maximum power AC3 duty(kw)Rated current(A)Type of enclosureCode numberSuitable thermal relay(A)220V230V220V230V415V440V500V660V690VLL(
Timer relay Timer relay(relay,time relay,mini relay)Rated voltages: 220 to 240V AC, 50/60Hz (110V AC optional) AC power consumption: 3W approximately Adjustable
Monitoring Relay Monitoring Relay(Voltage Relay,protection relay,power relay) Pated frequency:50/60Hz+/-5% Power dissipation:30VA max Control of phase sequence,total
Thermal over-load relay Thermal over-load relayis used in AC 50Hz (or 60Hz), rated work voltage is up to 660V, for protecting AC motor against overload or phase-breaking.
Mini power relay JZX-18FH Mini power relay Name: JZX-18FH Power Relay Features * 7A switching capabilities. * 2 to 4 pole configurations. * 1.5KV dielectric coil to contacts.
Reactive power control relays eactive Power Control Relays Name: JQX-62F-1Z,2Z Power Relay JQX-62F-2Z Power Relay JQX-62F-1Z Power Relay Contact Data Contact Ratings1Z,1H,1D 2Z,2H
22A LS Thermal Overload Relay STH-22A thermal overload relay installing with SMC-9,12,18,22 contactor directly. Through mounting brackets(AZ-22H)can be installed with rail or scre
Time switch Timer Time switch,Timer Voltage AC 110 240V DC 12 24V 50/600HZ Contact Timed SPDT Timing range circulation per week or da
Time switch Relay SUL181h timer,time switc
Water Level Controller Relay Relay (liquid level control) Voltage DC 24V DC 220V AC24V 380V Contact Capacity AC220V 5A DC24V 7
Phase failure and phase sequence Protection Relay Relay(Phase failure Relay,Over voltage Relay) Voltage:AC 380V/50HZ Contact Capacity:AC 220V:5A DC24V:7A Timing Range :(open-phase wrong phase sequenc
Electronic Overload relay,Thermal Overload Relay Electronic Overload relay,Thermal Overload Relay Overload and Phase Loss Protection Independently adjustable starting and Trip Delay Visual Current S
Time Relay,Timer H3CR-A8(Time Relay,Timer) VoltageAC24 240V 50HZ DC 12 48V Timing range0.05s 300
HYP600 Protection Relay 1.Multi-interface:8CT, 4PT, 3AI, 16/32DI, 11/16DO; 2.Multi-communication interface:1RS485, 1CAN, 1RS232 adjustment, two ethernet and one set fiber;
JRS2 (3UA) Thermal Relay JRS2 (3UA)thermal relay is suitable for general AC motor of long or discontinuous long operation with rated frequency of AC 50Hz, voltage up to 660-1
'Time Relay' 1.Voltage: AC 24,48,60,110,220,240V 50Hz DC24,48V 2.Contact: AH-1Timed SPDT AH2: Timed 2PDT AH3: Timed 3.Operation: AH-1: Time-limited operation/self
solid state relay solid state relay We are manufacturer. Load Current: 10A/15A/20A/25A/30A/40A/50A/60A/75A/80A/90A/100A/120A Load Voltage: 660VAC Control Voltage: 5
Telecom Relays / KLS-FL4102E series Telecom Relays / KLS-FL4102E series : General description :TypeFL4102EOutline15.8 X 10.8 X 11.8L x W x HFeatures1. Small size and low cost2. DIP stan