H.V current limiting fuse type W for motor protect Applications H.V HRC current-limiting fuses type W for motor protection is mainly used in AC 50Hz, rated voltage 3.6-10KV, rated current up to 400A(
High Voltage Current Limiting Fuse types XRNP Applications H.V HRC current-limiting fuses type XRNP for transformer protection is mainly used in AC 50HZ, rated voltage 3.6-40.5KV, rated current u
drop out fuse Description 1. Type: fuse cutout, drop out fuse cutout SRF-1 Drop out fuse cutout is of outdoor used high voltage protective device. To be connect w
high voltage drop out fuse cut out Description 1. Type: fuse cutout, drop out fuse cutout SRF-3 Drop out fuse cutout is of outdoor used high voltage protective device. To be connect w
oscillators FUSES Bussmann HINODE RENESAS CRYSTAL EPCOS,KDS,MURATA,NDK,KDS
JRM SERIES TEMPERATURE PROTECTOR FOR BATTERY PACK BeSuitablefortemperaturecontrolandprotectionagainstover-temperatureinbatterypacksofcordlesspowertools,lowvoltageappliance. ACTIONTEMPERATURE:-20 180(
10-15KV EXPORT TYPE Fuse Type: PD3series PD3-12/100A & PD3-12/200A Classification:Drop-out fuse cutout Cutout Fuse Polymer fuse cutout Technical parameters: Rated vol
15KV-27KV DROPOUT FUSE CUTOUT The technical parameters of typical: TypeRatedVoltage (KV)RatedCurrent (A)BreakingCurrent (A)ImpulseVoltage(BIL) (KV)Powerfrequency withstandoltage (
15KV Expulsion Fuse Cutout The technical parameters of typical: TypeRatedVoltage (KV)RatedCurrent (A)BreakingCurrent (A)ImpulseVoltage(BIL) (KV)Powerfrequency withstandoltage (
24-27KV/100A 200A Cut Out Fuse Technical parameters: PD-24/100A 1) rated voltage:24KV 2) rated current:100A 3) breaking voltage:8000A 4) power frequency withstand voltage:65KV 5) l
10KV 250MM Leakage Distance Drop out Fuse Technical parameters: TypeRatedvoltage (KV) Ratedcurrent (A)Breakingcurrnet (A)Impulsevoltage(BIL) (KV)Powerfrequency withstandvoltage(KV)Leakagedis
24-27KV Drop out Fsue Cutout with Silicone rubber Technical parameters: Type: HPD1-24/100A 1) rated voltage: 24 KV 2) rated current: 100A 3) breaking voltage:8.0 KA 4) power frequency withstand volta
15-27KV Open Fuse Cutout Technical parameters: Type: PD3-15F/100A 1) rated voltage:15 KV 2) rated current: 100A 3) breaking voltage:8.0 KA 4) power frequency withstand voltag
Expulsion Fuse Element Type: Expulsion Fuse ElementTo be connected with incoming feeder of distribution transformers or distribution lines, ZNF series drop-out fuse cutouts
GW9-12 outdoor high voltage disconnector Model GW9-12 outdoor high voltage isolated swtich is single phase AC 50HZ high voltage switch equipment,it is used in the power system which the rate
NT H.R.C Low Voltage Fuse General 1.1 NT low voltage H. R. C. Fuse has features of light in weight, small in size, low in power loss and high in breaking capacity. This produ
RL6 Fuse Type RL-16ND RL6-25 RL6-63 Rated voltage 500V 500V 500V Rated current of fuse 25A 25A 63A Rated current of fusant 1,2,4,6,10A 2,4,6,10,16,20,25A 35,5
YCH5 Bar and Fuse type switch disconnector General YCH5 series bar and fuse type switch disconnector is applicable in the circuit of rated voltage AC 660V and below,rated current AC16 0A-630A,
High Voltage Current Limited Fuse for Voltage Tran Type Rated voltage (kV) Rated current (A) Rated breaking current (kA) XRNP-12 11/12 0.5,1,2,3,15 40 XRNP-12X Type Rated voltage (kV) Rated current (A
High Voltage Fuse We supply low voltage and high voltage fuse
NT fuse NT fuse Being light in weight, small in size, low in power-loss and high in breaking capacity. This fuse has been widely used in power-load and short
limit-current fuse for protection transformer Wholly scope high voltage limit-current fuse for protection transformer This product can be used in indoor system of 50hz and rated voltage 12kv, it
car fuse gold planted car fuse gold planted Zince material,plastic jacket Spec:1A-40A,32V RoHS complian
Auto Fuse 6x30 5x20 From 1A to 30A 6x30 From 1A to 30
Blade Fuse car fuse,automotive fuse,glass fuse,electric fuse,bel fuse,electronic fuse,auto fuse,fuse clip,fuse links,blade fus
A-F series(2A) Thermal fuse/Thermal link/Thermal c Thermal fuse/Thermal link/Thermal cutoff Model No.: A1-F Rated Functioning Temp.(Tf): 102CFusing-off Temp.: 98±2CHolding Temp.(Th): 79CMaximum
KW thermal protector for motor KW temperature protector Scope of Application: Air-conditioning fan motor,fan coil motor,wind screen TV motor, washing machine motor, dryer motor, DC
thermal overload protector for water pump,air comp thermal overload protector motor thermal protector,thermal device,temperature controller,thermostat,bimetal thermostat Table of Specification.. Model
17AM Thermal Protector for ballast,domestic applia 17AM Thermal Protector for ballast Table of Specification Model of Our CompanyModel of Our CompanyComparison of International17AMG 5017AMG 11017AMG 0
Fuse Cutout Drop out fuse cutout is composed of insulator supports and fuse tube. Static contacts is fixed on two sides of insulator support and moving contact i
High Voltage Fuse Tube,Limiting Fuse,Indoor Fuses 1. We are willing to customize for each new product 2, if you need our product information, please leave a detailed address, so that we can express s
Removable arrester,drop out Fuse Lightning Arreste 1. We are willing to customize for each new product 2.Supply all the components and accessory of High Voltage Switchgear 3. if you need our product i
limiting current limiting current Must be determined before orderingRated voltage, rated current, indoors or outdoors, phase distance, ceramic or silicon rubber or re
24KV 20KV 21KV 27KV high voltage fuse high voltage fuse 1. We are willing to customize for each new product 2.Supply all the components and accessory of High Voltage Switchgear 3. if you
High-voltage Isolate Switch GW7 High-voltage Isolate SwitchSummary: GW7 outdoor disconnecting switch is AC 50Hz outdoor HV equipments, there are 40.5kv 72.5kv and 126kv rated voltag
33KV Drop-out Fuse Key words : 33KVDrop-out Fuse,Falling type fuse,High voltage fuse,Arrester,SPD and so on Rated voltage:10KVRated current:100A 200A General descriptio
Fuse NT H.R.C Low Voltage Fuse with wide range, various type. For more information, please go for our website
Drop-out Fuse Drop-out Fuse, has wide range: 12KV-15KV 10KV-15KV 15KV-27KV 24KV-27KV 27KV-33KV 33KV-36KV 30KV-33KV 36KV-38K
Single pole main switch fuses 30A(2x15A) Main switch---single pole distribution switch fuses Rated Voltage: 250V A.C Rated Current: Switch 30A Fuses 2x15A 2871 Single pole distribution swit
11-33KV CUT OUT FUSE cut out fuse material:porcelain or sillicon(polymer
Cut Out Fuse Drop out fuse cut out and and load switching fuse cutout are of outdoor used high voltage protective device. To be connected with incoming feeder of
Drop-out Fuse Cutout Drop-out fuse cutout and load switching fuse cutout are outdoor high voltage protecting device, they are connected with the incoming feeder of the di
Fuse Cutout with Porcelain Base Fuse Cutout withPorcelain Base is an outdoor protection productfor power system against over-load and short-circuit failure as well as a device for o
Plug-in Type HRC Fuse Plug-in Type HRC Fuse Overview: Plug-in Type HRC Fuseis used to protect transformers, capacitor banks, cable and overhead lines against short-circuit
Cutout Fuse SJC-16
Drop Out Fuse / Fuse Cutout / Cutout Fuse SJC-19 Drop Out Fuse / Fuse Cutout / Cutout Fus
Cutout Fuse
Drop Out Fuse / Fuse Cutout / Cutout Fuse SJC-28 SJC-28 Drop Out Fuse / Fuse Cutout / Cutout Fuse type rated voltage(KV)rated current(A)breaking current(KA)impulse voltage BIL(KV)power frequency wit
Drop Out Fuse / Fuse Cutout / Cutout Fuse SJC-29 Drop Out Fuse / Fuse Cutout / Cutout Fuse type ratedvoltage(KV)ratedcurrent(A)breakingcurrent(KA)impulsevoltageBIL(KV)powerfrequencywithstandvoltage(
Drop Out Fuse SJC-5 Drop Out Fuse type rated voltage(KV)rated current(A)breaking current(KA)impulse voltage BIL(KV)power frequency withstand voltage(KV)leakage distance(