Weight |
0.54Kgs |
Place of Origin |
Zhejiang China (Mainland) |
Brand Name |
HANRI |
Model Number |
T-50A |
Input Voltage |
110V |
Output Voltage |
5V 12V -5V in one channel |
Output Power |
1 - 50W |
Output Type |
Triple |
Competitivedprice and high reliability 105oC Output capacitor AC input power suitable for the world High efficiency and low operation temperature Soft-start current can reduce the AC input impact effeciticly With short-circuit and overload protection Compact size, light weight 100% full-load burn-in test Installed with EMI filter, minimum waveModelT-50AT-50BT-50CT-50DCH1CH2CH3CH1CH2CH3CH1CH2CH3CH1CH2CH3DC output voltage5V12V-5V5V12V-12V5V15V-15V5V12V24VOutput voltage range(Note:2)±2%±5%±5%±2%±5%±5%±2%±5%±5%±2%±6%±6%Rated output current7A1A1A5A1A1A4A1A1A3A1A1AOutput current range0.6-7A0.2-1A0.2-1A0.6-5A0.2-1A0.2-1A0.6-1A0.2-1A0.2-1A0.6-4A0.2-1.2A0.2-1.2AWave and noise(Note:3)100mV100mV100mV100mV100mV100mV100mV100mV100mV50mV120mV120mVInlet stability(Note:4)±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±1%±1%Load stability(Note:5)±1%±4%±4%±1%±4%±4%±1%±4%±4%±1%±5%±5%DC output power52W49W50W51WEfficiency66%69%71%72%Adjustable range for DC voltageCH1; +10, -5%CH1; +10, -5%CH1; +10, -5%CH1; +10, -5%Input current1.6A/115V 0.8A/230VAC inrush currentCold-start current 20A/115V 40A/230VLeakage current<0.5mA/240VACOverload protection105% 150% Type: pulsing hiccup shutdown Reset: auto recoveryTemperature coefficient±0.03%/°c(0 50°c)ON+5VSetup, rise , hold up time200ms, 50ms, 16msVibration10 500Hz, 2G 10min,/1cycle, Period for 60min, Each axesWithstand voltageInput and output internal: Input and encolsur: 1.5KvAC, Output and enclosure: 0.5KvACIsolation resistanceInput and output internal: Input and enclosure, Output and enclosure:500VDC/100MΩWorking temperature and humidity-10°c +60°c(Refer to output derating curve), 20% 90%RHOverall dimension159×97×38mmWeight0.54KgsSafety standardsMeet UL 1012 requirement (Not apply for the mark)Note: 1. The testing condition for the paramenter above is: 230VAC input, rated load, 25°c 70% RH. Temperatuer. 2. Error: include the setting error, line stability and load stability.(Note:5). 3. Wave test: adopting "A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting. 4. Inler woltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage5. Load stability test: The load is from 0% to 100%, others 60%. 6. Total output canba maximum Current, total load can not exceed the maximum output power.