Place of Origin |
Zhejiang China (Mainland) |
Brand Name |
HANRI |
Model Number |
S-350-27 |
Input Voltage |
110V |
Output Voltage |
27V |
Output Current |
13A |
Weight |
1.15Kgs |
Output Power |
301 - 400W |
Output Type |
Single |
S-350 series switching power supply competitivedprice and high reliability 105oC Output capacitor AC input power suitable for the world High efficiency and low operation temperature Soft-start current can reduce the AC input impact effeciticly With short-circuit and overload protection Compact size, light weight 100% full-load burn-in test Installed with EMI filter, minimum waveModelS-350-5S-350-7.5S-350-12S-350-13.5S-350-15S-350-24S-350-27S-350-48DC output voltage5V7.5V12V13.5V15V24V27V48VOutput voltage range(Note:2)±2%±2%±1%±1%±1%±1%±1%±1%Rated output current50A40A29A25.8A23.2A14.6A13A7.3AOutput current range0-50A0-40A0-29A0-25.8A0-23.2A0-1406A0-13A0-7.3AWave and noise(Note:3)150mVp-p150mVp-p150mVp-p150mVp-p150mVp-p150mVp-p200mVp-p240mVp-pInlet stability(Note:4)±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%Load stability(Note:5)±1%±1%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%DC output power250W300W348W348.3W348W350.4W351W350.4WEfficiency73%76%74%79%78%81%82%83%Adjustable range for DC voltage4.5 5.6V6 9V10 13.2V12 15V13.5 18V20 26.4V26 32V41 56VInput current6.5A/115V 4A/230VAC inrush current25A/115V 50A/230VLeakage current<3.5mA/240VACOverload protection105% 150% Type: pulsing hiccup shutdown Reset: auto recoveryOver-voltage protection5.75 6.75V9.4 10.9V13.8 16.2V15.5 18.2V18 21V27.6 32.4V33.7 39.2V57.6 67.2VHigh-temperature protectionERH3>=65 70°c Fan on, <=55 60°c Fan off,>=80 85°c, Cut off ouput(5 15V) (24 48V)Setup, rise , hold up time200ms, 100ms, 20msVibration10 500Hz, 2G 10min,/1cycle, Period for 60min, Each axesWithstand voltageInput and output internal: 1.5KvAC, Input and enclosure:1.5KvAC, Output and enclosure:0.5KvACWorking temperature and humidity-10°c +60°c(Refer to output derating curve), 20% 90%RHWeight1.15KgsSafety standardsDesign refer to Ul 1950EMC standardsDesign refer to FCC Part 15J Part 15 J class ANote: 1. The testing condition for the paramenter above is: 230VAC input, rated load, 25°c 70% RH. Temperatuer. 2. Error: include the setting error, line stability and load stability.(Note:5) 3. Wave test: adopting "A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting. 4. Inlet woltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage. 5. Load stability test: The load is from 0% to 100%