300G under tank No Tank RO water purifier with co

300G under tank No Tank RO water purifier with co

Shanghai, China
Production capacity:
10000 Piece / Month
Shanghai, China
Company
86-21-59757323
Larry Zhu
Contact person

Basic Information

Power (W) 28
Voltage (V) 220
Place of Origin Shanghai China (Mainland)
Brand Name AQUA JB
Type Reverse Osmosis
Use Under Sink
StageDescriptionComponent NO.Function1st5mic pp FilterPP-10Remove the particles, dust, mud, etc. 2ndGranular Carbon FilterGAC-10Remove the chlorine, organics, odor smell turbidity etc.3rdBlock carbon filterCTO-10Remove the chlorine, organics, odor smell and suspending particles4thRO membraneCSM,FCS,FILMTECRemove the bacteria, heavy metal, salt, bad mineral substance and other dissolved matter5thPost inline carbon filterT-33Adjust the taste Product feature With the import reverse osmosis membrane of famous brand (RO membrane ), this product applies first class reverse osmosis technical and technology to product pure water . 5 stages filtration , synthesize to play strain each the effective role of core ,clear away other harmful impurities ,suspension thing ,colloid ,organic meter ,heavy metal ,solubility solid ,germ ,virus, thermal source and the silt in source water .only retain water molecule and dissolved oxygen . With the import famous brand high –pressure mute pump ,the service life is long and the quality is reliable . With the function of high –pressure membrane washing (hand control ) ,RO membrane life can be prolonged efficiently .The course of producing water is controlled automatically (the system will stop when source water stops or pressure tank is full ) Major technical parameters : The voltage and frequency of power source :230V/50 60Hz (optional if with pump ) Total input power :18 W (optional if with pump ) Pure water output :50 GPD/ 75 GPD/ 100 GPD (25°C) Suitable source water pressure :0.1 0.3 Mpa Permitted environmental temperature :5 40 °C Usage: Flushing Filters :When using pure water machine for the first time ,filter should be flushed as following step : Open the inlet water ball valve ,open RO bypass flush valve ,insert the plug of power supply in the socket of power ,booster pump starts work ,concentrate emission port begins to emission concentrate water .After flushing process is complete ,open diverter valve in pressure tank ,close RO membrane flushing ball and now begin to produce pure water ,at the same time concentrate emission flux dropped obviously . Maintenance : Replace cartridges regularly to maintenance water quality .Make sure each filter works effectively and guarantee water quality to pass standard .If cartridges are changed regularly ,pure water machine users can enjoy high quality pure water permanently .Cartridge replacement period depends on the source water quality and the consumption of pure water .Following are the suggested replacement period of each filter on the basis that the source water is city running water. First stage filter :3 to 6 months Second stage filter :4-9 months Third stage filter(RO Membrane ) :5-10 months Fourth stage filter : 12-24 months Cartridge replacement period depends on the pure water consumption and the source water quality .If adopt safety replacement frequency mentioned above, the pure water quality can be guaranteed .Therefore above suggestions are for reference only . RO membrane flush :During the source of pure water producing ,RO membrane surface will be begrimed with impurity and germ .Therefore water quality will drop .So regular RO membrane washing is needed . Following are flushing steps: Close diverter valve of pressure tank ,open long reach faucet ,RO booster pump starts (must confirm booster pump have started );open bypass washing valve ;make RO membrane flush ,concentrate water is discharged .After flushing finished close bypass washing valve ,open diverter valve in pressure tank ,close long reach faucet .Washing time is 15 minutes . To prolong system service life and guarantee pure water quality and quantity ,users can adjust flushing frequency and flushing time according the quality of local city running water Notice 1. Please do not take apart the element parts on machine in case of leakage or damaging the machine . Pressure tank have an air vent and do not deflate it .Do not use the disproportional power source instead of voltage rating .If the system is not in use for a long period of time ,the plug of power source should be pulled out (optional if with pump ),and the inlet water ball valve should be shut to cut off source water .After long term out of service ,when using again should follow the operation as the first time .Careful handing is necessary during shipping ,moving and installation .

Delivery terms and packaging

Packaging Detail: Carton Delivery Detail: 30 days after deposit
Port: Shanghai

Payment term

Letter of credit

Telegraphic transfer

Фотографии

    Password recovery
    To recover your password, please enter in the box below your email address with which you have registered:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    An error has occurred. Please check your e-mail address and try again.
    Ваш новый пароль:

    Name is empty


    Выберите страну доставки

    You have not written a message

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    Your message has been sent!

    Close

    1
    Рынок B2B
    Cancel Close
      Show more close
        Area search
        Worldwide
        Категории
          Product