Model Number S-240series
Input Voltage 220V
Weight 1.1Kgs
Output Power 201 - 300W
Output Type Single
Competitivedprice and high reliability 105oC Output capacitor AC input power suitable for the world High efficiency and low operation temperature Soft-start current can reduce the AC input impact effeciticly With short-circuit and overload protection Compact size, light weight 100% full-load burn-in test Installed with EMI filter, minimum waveModelS-240-5S-240-7.5S-240-12S-240-15S-240-24S-240-30S-240-48DC output voltage5V7.5V12V15V24V30V48VOutput voltage range(Note:2)±2%±2%±1%±1%±1%±1%±1%Rated output current40A30A18A15A10A8A5AOutput current range0-40A0-30A0-18A0-15A0-10A0-8A0-5AWave and noise(Note:3)150mVp-p200mVp-p150mVp-p150mVp-p180mVp-p180mVp-p240mVp-pInlet stability(Note:4)±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±1%Load stability(Note:5)±1%±1%±0.5%±0.5%±0.5%±0.5%±1%DC output power200W225W216W225W240W240W240WEfficiency78%80%82%83%85%85%87%Adjustable range for DC voltage4.5 5.8V6 9V10 14V12 18V120 28V27 233V41 56VInput current5A/115V 2.5A/230VAC inrush current18A/115V 36A/230VLeakage current<3.5mA/240VACOverload protection105% 150% Type: pulsing hiccup shutdown Reset: auto recoveryOver-voltage protection6 7V9.4 10.9V14.4 16.8V18.5 21.5V31.2 36V34.5 40.5V57.6 67.2VHigh-temperature protectionERH3>=65 70°c Fan on, <=55 60 °cFan off,>=80 85°c, Cut off ouput(5 15V) (24 48V)Setup, rise , hold up time1ms,20ms, 20msVibration10 500Hz, 2G 10min,/1cycle, Period for 60min, Each axesWithstand voltageInput and output internal: 1.5KvAC, Input and enclosure:1.5KvAC, Output and enclosure:0.5KvACWorking temperature and humidity-10°c +60°c(Refer to output derating curve), 20% 90%RHWeight1.1KgsSafety standardsUL 1950, EN60950EMC standardsEN55022, EN55204, EN61000, IEC8012,3,4, IEC555-2Note: 1. The testing condition for the paramenter above is: 230VAC input, rated load, 25°c 70% RH. Temperatuer. 2. Error: include the setting error, line stability and load stability.(Note:5) 3. Wave test: adopting "A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting. 4. Inlet woltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage. 5. Load stability test: The load is from 0% to 100%

Delivery terms and packaging

Port: Ningbo

Payment term

Telegraphic transfer

Western Union

Фотографии

    Password recovery
    To recover your password, please enter in the box below your email address with which you have registered:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    An error has occurred. Please check your e-mail address and try again.
    Ваш новый пароль:

    Name is empty


    Выберите страну доставки

    You have not written a message

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    Your message has been sent!

    Close

    1
    Рынок B2B
    Cancel Close
      Show more close
        Area search
        Worldwide
        Категории
          Product