35KV Top-Transformator Transformer:35KV top-type transformer MVA Ratings:20MVA Voltages:35KV LTC:ABB Bushings:AB
Stromwandler
Stromwandler Rated second current:25mA,10mA Ratio:1000:1 2500:1 Rated primary current:25A Phase error (rated input):<15' Linearty:0.1% Accuracy calss:0.1 Diele
Stromwandler Rated primary current:5A Rated second current:10mA,5mA Ratio:500:1 1000:1 Phase error (rated input):<20 Linearty:0.5% 0.2% Accuracy calss:0.5 0.2
Stromwandler Rated second current:30mA,24mA Ratio:2000:1 2500:1 Rated primary current:60A Phase error (rated input):<10' Linearty:0.1% Accuracy calss:0.1 Diele
Stromwandler Rated primary current:5A Rated second current:5mA,2.5mA,2mA Ratio:1000:1 2000:1 2500:1 Primary current range:0 20A Phase error (rated input):<10'
Stromwandler Rated primary current:1.5A 2.5A 5A Rated second current:5mA Ratio:300:1 500:1 1000:1 Primary current range:0 20A Phase error (rated input):<15' Li
Motor mit Stromwandler Schutz
Stromwandler Rated primary current:20A Rated second current:10mA 10mA Ratio:1000:1 2000:1 Primary current range:0 100A Phase error (rated input):<15' Linearty:
Stromwandler Rated primary current:10A Rated second current:10mA 5mA Ratio:1000:1 2000:1 Primary current range:0 60A Phase error (rated input):<15' Linearty:0.
Stromwandler Current-voltage transformer, which is actually the primary and secondary turns ratio of 1:1 of the current transformer, used be in the primary series
Messwandler High Voltage Instrument Transformer, Indoor & Outdoor type; High Voltage Transformer, Current Transformer KEMA type tes
220kV Kondensator Spannungswandler 1. General It is outdoor, single phase and oil capacitor voltage transformer, which is used for metering and relay protection of 220kv, 50HZ or 60HZ
35KV Leistungstransformator
40.5kv unter Stromwandler 40.5KV below Current Transformer, Indoor type, Outdoor type, Post type, Bushing type, Bus typ
132KV Spannungswandler KEMA Type Test, Outdoor, Oil-immersed inductive type, single phase, used for metering and relay protection, applying to highland area, individual mea
245 kV Stromwandler 220KV Current Transformer, Outdoor, Oil-immersed hair-pin type, used for metering and protection, single phase, applying to highland area, with prote
220kV Stromwandler 1. General 220KV Current Transformer, Outdoor,KEMA Type Test,Oil-immersed hair-pin type, used for metering and protection, single phase, applying to
40.5kv Spannungswandler JDZX9-35Q JDZX9-35C JDZX-35D full enclosed indoor type single phase voltage transformer, full operation mode, residual voltage winding, casting insul
15-40.5KV Außenstromwandler full operation mode, outdoor type, casting insulation, post type, current transformer Technical Data:two windings Rated primary current(A) Accuracy c
132KV Stromwandler 1. GeneralKEMA Type Test, Outdoor, Oil-immersedHair-Pin type, used for metering and protection, applying to highland area, with protective class, sin
S9 Serie Voll versiegelt Leistungstransformator high efficiency,low lossThe three-phase oil-immersed distributing transformer applies new type insulating structure and makes short-circuit resistanc
Trocken-Verteilungstransformator Product standard: GB6450, GB/T10228 Rated high voltage: 10(11,10.5,6,6.3)KV Rated low voltage: 0.4KV Link group: Yyn0 or Dyn11 Insulation level: L175
Dosierbehälter SJWL-35 high-voltage electric metering tan
Spannungswandler JSZK2-6, 10 dry-type outdoor voltage transformer Technical date Typ
JDZ72-12 Typ Outdoor-Spannungswandler JDZ72-12 type outdoor voltage transforme
JLSZ-6, 10 Typ Outdoor kombiniert Transformator JLSZ-6, 10 type outdoor combined transforme
Messwandler The product has fuse which can protect switchgear .The surface is metallic layer,which can be grounding directly. The products according with the sta
Messwandler This 24kV voltage transformer matched with CGIS is located outside of the gas compartment .The products according with the standards of GB1207,IEC600
Messwandler The rated frequency 50 or 60Hz and rated secondary current 5 or 1A.Its surface is resin-cast insulated.The products accord with the stands of GB1208,
Messwandler The rated frequency 50 or 60Hz and rated secondary current 5 or 1A.Its surface is resin-cast insulated.The products accord with the stands of GB1208,
Messwandler The are used for metering electric energy .voltage control and reply protection in the electric system with rated frequency 50 HZ or 60HZ and rated v
Messwandler It is the high voltage of incurrent transformer,according to Siemens required for research&development.The products have passed through Quality I
Messwandler
Messwandler The indoor current transformer of type CSR1-12/1528 is costing resinspost type,with protective class and fully enclosed product .It is used for meter
ZGS11 Series American Type Package Substatiom ZGS11 Series American Type Package Substatiom The productof power transformeris the same with place which electro-area, such as living area, emporia,
ZBW11 Series Europäischen Typ Verpackung Substation Substation The package substation is a kind of outdoor distribution set device with 50HZ,10KV. Using a especially design to put high and low voltage
SZ11-Serie Power Transformer ausgestattet mit Last Superior performanceof this power transformergets to the international level. It can save energy in evidence. Comparing to GB6451-1999, its no-load l
SCB10 Series Harzguss-Trocken-Transfor Superior performance of this power transformergets to the international level. Safe, fireproof, can be set at the charge center directly. Maintenance
SCB10 Harzguss-Trocken-Leistungstransformatoren 200 Superior performance of this power transformergets to the international level. Safe, fireproof, can be set at the charge center directly. Maintenance
SZ11-Serie Power Transformer ausgestattet mit Last Superior performance of this power transformergets to the international level. It can save energy in evidence. Comparing to GB6451-1999, its no-load
S11 Series 10KV Sealed Power Transformer Superior performance of this power transformergets to the international level. It can save energy in evidence. Comparing to GB6451-1999, its no-load
S11 Series 10KV Sealed Power Transformer Superior performance of this power transformergets to the international level. It can save energy in evidence. Comparing to GB6451-1999, its no-load
S13-M.RL 3-Dimensional Wound Kernölbadge Pow This power transformerusing three-phrase three-dimensional wound core structure and its magnetic circuit symmetry, compact structure, superior perfor
S11 Series 20KV Sealed Power Transformer Superior performance of this power transformergets to the international level. It can save energy in evidence. Comparing to GB6451-1999, its no-load
Stromtrockentransformatoren 10kV Grade S11 Series non-excitation power transformers performance parametersrated capacityKVArated voltageVoctor groupNo-laod lossWLoad lossWNo-lao
Mining Druckfeste trocken Transformator / 10KV KBSG Series mining transformer applies not only to mine environment filled with gas mixture of methane and coal dust (exist explosive danger)., and n
Bergbau explosionsgeschützte beweglichen Substation / 10KV KBSGZY Series mining transformer (Movable Substation) applies not only to mine environment filled with gas mixture of methane and coal dust (exist ex
Leistungstransformatoren 10kV Grade S11 Series non-excitation power transformer performance parameters rated capacityKVArated voltageVoctor groupNo-laod lossWLoad lossWNo-la
Bergbau druckfeste bewegliche Umspannwerk / 6KV KBSGZY Series mining transformer (Movable Substation) applies not only to mine environment filled with gas mixture of methane and coal dust (exist ex