Intelligent Air Frame Circuit Breaker (HKKW1-2000) HKKW1 series intelligent air circuit breaker is suitable for the circuit of AC 50Hz with rated voltage 400V, 690V and rated current up to 6300A. It
Fehlerstromschutzschalter HKKC1L-63-3P Rated voltage:single for 230V and two,three ,four for 400V. Rated current:3A,6A,10A,16A,20A,25A,32A,40A,50A,63A. HKKC1L-63 series residual current mi
AC Kompakt-Leistungsschalter HKKM1 series Product developed and manufactured by international advanced technology Rated insulation voltage: 800V AC 50Hz Rated operating voltage:
630A Kompakt-Leistungsschalter HKKM1 series Product developed and manufactured by international advanced technology Rated insulation voltage: 800V AC 50Hz Rated operating voltage:
10kA Mini Circuit Breaker Model No:TSM9Rated Current:1A 63ARated Voltage:230Vac(1P), 400Vac(2/3/4P)Characteristic Curve:B, C, DNo. of Pole:1P, 2P, 3P, 4PBreaking Capacity:1000
Ministromunterbrecher Model No:DZ47Rated Current:1A 63ARated Voltage:230Vac(1P), 400Vac(2/3/4P)Characteristic Curve:B, C, DNo. of Pole:1P, 2P, 3P, 4PBreaking Capacity:6000
LS MCB Model No:BKN,LSRated Current:1A 63ARated Voltage:230Vac(1P), 400Vac(2/3/4P)Characteristic Curve:B, C, DNo. of Pole:1P, 1P+N, 2P, 3P, 3P+N, 4PBreaking
L7N Mini Circuit Breaker Model No:L7Nrated current(Ue)230v/400;50/60HZRated breaking capacity10KA IEC898(0.5-63A) 15KA ICE947-2(0.5-63A) Short circuit breaking capacity of DC
ID Fehlerstromschutzschalter Model No:IDRated Current:16, 25, 40, 63, 80, 100ASensetivity:10, 30, 100, 300, 500mARated Voltage:230Vac(2P), 400Vac(4P)No. of Pole:2P, 4PType:Type A
PFIM FI-Schutzschalter Model No:PFIMRated Current:25, 40, 63, 80, 100ASensetivity:30, 100, 300, 500mARated Voltage:230Vac(2P), 400Vac(4P)No. of Pole:2P, 4PType:Type AC and
NSX MCCB The new generationMCCB of Schneider Electric Model: NSX Pole: 3P 4P Rated current: 100-630A Rated voltage: 400VA
Tmax Kompakt-Leistungsschalter Tmax MCCB The new generationABB MCCB Rating from 160A to 1250
Leistungsschalter NSX NSX circuit breaker is one of the most advance type breaker in the world, which adopts international advanced design and manufacture technology. They
FI-Schutzschalter (F7) F7 series Residual current circuit breaker(without over-current protection) is suitablefor the line of AC 50/60Hz, voltage 230V(2pole)/400V(4pole), r
Mini-Schutzschalter (L7) The product of L7 belong to the advanced level of the nineties in the world instead of the older generation of L7. They have protective function as s
Leistungsschalter (VW1) VW1 series intelligent universal circuit breakers could be used fir controlling the low voltage distribution net and keeping it safety. Installing in
Vakuum-Leistungsschalter ZN28-12 / ZN28A-12
mccb ENLM4C65 specification Technincal date Item C65,cc65h,c65l,c65nl Standard IEC 60898 IEC60947-2 IEC 60888 Rated current 6,10,16,20,25,32,40,50,63 Numb
mccb EN LM1 series moulded case circult breaker is applicable circuit of AC 50-60HZ. Rated insulation voltage 690v, rated operating voltage up to DC 250V
MCB ENLM4LC65 specification Technincal date Item C65,cc65h,c65l,c65nl Standard IEC 60898 IEC60947-2 IEC 60888 Rated current 6,10,16,20,25,32,40,50,63 Num
mccb ENLM2L series molded case circuit breaker is applicable circuit of AC 50HZ 60HZ. Rated insulation voltage 750v ,rated operating current up to 1250A,
CFM7 TMAX Kompakt-Leistungsschalter MCCB APPLICATION TMAXMouldedcasecircuitbreakerissuitableforcircuitAC50/60Hz,ratedvoltageuptoAC660V,ratedoperatingcurrentto630V. Itfeaturesnormalstructure,
CV-M Motorschutzschalter CV-M motor protection circuit breaker ApplicationUsed for the over-load and short-circuit protection of the motor Power circuit, as a full-voltage s
DPN Mini-Schutzschalter MCB CFB30-32 (DPN ) mini circuit breaker MCB Application The product is applicable to protect line conductor and overload , and short circuit of small si
RGKN Leitungsschutzschalter The design on the base of the current-limiting device increases the capability of Circuit breaking, with a max. of 6KA(AC 230V standard) The super-mi
DL7NL-40 RCBO (RCDMCB) Notice: The following picture is 3KA RCBO, its principle is same as 6KA RCBO. Scope of application DL7NL-40 earth leakage circuit breakers are mainly
FDL7 Mini Circuit Breaker Technical parameter Electric parameter: Up to electrical standard: EN60898 GB10963 IEC898 Rated voltage(Ue): 230/400V;50/60HZ Rated breaking capacity
FDF7 ELCB Fehlerstromschutzschalter Electric parameter: Up to electric standards: IEC61008(EN1008) GB16916.1-1997 Leakage operation time:non-time delayMin time delay 10msMin time delay
FDF364 FI-Schutzschalter Circuit Breaker TECHNICAL DATA:Tripping time:100ms(depending on specifications 5XIN400ms)Ambient temperature: -5°C +55°CClimatic resistance: 55°C/28 cycl
FDF7 RCD Electric parameter: Up to electric standards: IEC61008(EN1008) GB16916.1-1997 Leakage operation time:non-time delayMin time delay 10ms Min time dela
DRN-32 Miniatur-Leistungsschalter Main technical parameter Type of instantanenous release:(c5ln c10ln)Rate voltageAC 250V,50/60HzRate Current6A 3ARate short circuit make and break cu
FDL5-63 MCB Rated temperature 400CRated voltage 240V/415V ACRated current(C):1,3,5,6,10,15,16,20,25,32,40,50,60,63A (D):1,3,5,6,10,15,16,20,25,32,40AElectric end
Leitungsschutzschalter MCB Number of Pole
MCB Number of Pole
transparent Brecher Number of Pole
DC MCB Meet the standard of IEC 60898-2, GB 10963.2 Wiring diagram
DC MCB Schalter Meet the standard of IEC 60898-2, GB 10963.2 Wiring diagram
DRNL-32 RCBO NOTICE: The color of handle can change as your request. Scope of application DRNL-32 earth leakage circuit breakers are mainly applied to the AC 50Hz
DC-Leistungsschalter MCB Meet the standard of IEC 60898-2, GB 10963.2 Wiring diagram
FD MCCB APPLICATION NF series circuit breaker is features of reliable working out and steady performance, reasonable structure, beautiful appearance and smal
Circuit Breaker DZ47-63 series circuit breaker is used in lighting distribution system or motor distribution system for protecting overload and short-circuit in the
F360 Circuit Breaker ApplicationF360 series circuit breaker for AC 50HZ or 60HZ, rated voltage 240V/415V, rated current of the circuit 63A. Of lines due to short-circuit
ZW11-12 Hochspannungs-Vakuum-Leistungsschalter (outdoo ZW11-12 designed and developed for 10kV delivery side of 110 220kV transformer to supply demostic barren proprietary product (patent No. ZL 01 2 1347
Ministromunterbrecher Mini circuit breaker Features: 1) Voltage: 230V / 400V 2) Current (A): 6, 10, 16, 20, 25, 32, 40, 50, 63 3) Specifications: 1P, 2P, 3P, 4P 4) Usa
DZ12-Leistungsschalter (Leistungsschalter) DZ12 circuit breaker Applications: 1) DZ12 series molded case circuit breaker are mainly applied to AC 50Hz, rated current to 63A, single phase 230V
Circuit Breaker Applications: 1) DZ12 series molded case circuit breaker are mainly applied to AC 50Hz, rated current to 63A, single phase 230V and three-phase 400V
Schutzschalter DZ47LEseries leakage circuit breaker is suitable for circuit of AC 50Hz,rated voltage 240 415V,rated current 63A,with protection functions of leakage
Schutzschalter The material of enclosure and parts is fire-resistance and shock withstanding . It is suitable for circuit of AC 50/60Hz,rated working voltage 415V b
Fehlerstromschutzschalter DZ47LEseries leakage circuit breaker is suitable for circuit of AC 50Hz,rated voltage 240 415V,rated current 63A,with protection functions of leakage
Fehlerstromschutzschalter STLD series leakage circuit breaker is suitable for circuit of AC 50Hz,rated voltage 240 415V,rated current 63A,with protection functions of leakage,