Ort der Herkunft |
Guangdong China (Mainland) |
Marke |
Eastsun |
Modell-Nummer |
TT80kva |
Ausgangsspannung |
380 |
Optional configuration: 1.Can be increased capacity for the UPS system, the configuration up to 800KVA 2.Can be odd UPSs parallel , especially suitable for industrial process control 3.Can be used for N +1 or N + X as Redundant architecture to achieve the reliability of the system increases. 4.Can be selected RS485, dry contact and SNMP card etc. real-time remote monitoring network interface Optional the software-controlled for 3-month 5.automatic charge and discharge functions . Optional support communication converter modules ICP7520. Features of UPS of DSP technology control: 1.Simplify the control circuit to enhance the control flexibility and stability 2.Effectively reduce the number of the devices , significantly improve system reliability 3.Control precision, fast, reliable and stable 4.Output AVR is high precision, non-intrusive load power supply Perfect protection: 1.Input and output short-circuit protection 2.Batteries over-charge, over-discharge protection 3.Input over-low-voltage, over-high-voltage protection 4.Overload protection, over-temperature protection 5.The unique protection function of lacking phase and phase sequence detection. TypeTT80KTT100KTT120KTT160KTT200KTT250KTT300KNominal cappacity (KVA/KW)80/64100/80120/96160/128200/160250/200300/240RectifierRectifier way6 pulse/12 pulse12 pulseNominal voltageThree phase With four lines+ground wire,380VAC±25%Nominal frequency50HZ±10%,60hz±10%Voltage harmonic distortion<10%The largest output voltage446VDCVoltage harmonic distortion<10%The largest output voltage446VDCMicro-charge current set15A 40A(adjustable) 20 60A(adjustable)BatteryNumber units33pcsNominal battery voltage396VDCFloating voltage446VDCInverterNominal voltageThree Phase With four Lines+Ground wire,380VAC±1%Nominal frequencyCome after input frequency(commercial mode)50hz/60hz(Battery mode)Crest fatio3:1Output wave formSine waveTotal harmonic distortionLinear load <3%; non-linear load <5%Balance load voltage<±;(<± 3% unbalanced load voltage)Overload capabilityOver 125% , UPS turn-off after 10min,Over 150% , UPS turn-off after 1minefficiency, load 100%95SystemThe working and the principlePower-line,static bypass switch(continuous switch),double conversion technology,complele separation of power outputOperating temperature-20 40°CRelative humidity30% 90%Running high (maximum)<1000 (each additional 100 meters power fell 1% to a maximum 4,000 meters)CoolingForced ventilationNoise≤65dB(Distance 1m)≤70dB(Distance 1m)Size(W×D×H mm)1250×750×1650Weight(Kg)73088010001300152018302100Remark : (1)Specification only for reference .Subject to change without prior notice(2) We accept order with special specifications