Ort der Herkunft |
Guangdong China (Mainland) |
Marke |
Kedaups |
Modell-Nummer |
KD-3KVA |
Gewicht |
65KG |
Ausgangsspannung |
220V |
KD-SeriesUninterrupted Power System is well-designed for the safe protection of computer networks and sophisticated electronic equipment, electrical equipment at complex network environment. Adopting on line double conversion technology, zero interrupt conversion, can completely eliminate all kinds of network interference and failure in providing clean power for the load to ensure the load equipment run efficiently. AC / DC input with harmonic suppressors, so that UPS have no harmonic pollution to the electricity grid; DC / AC inverter uses international advanced SPWM pulse width modulation technology, IGBT power module and the output isolation transformer so that UPS can output stable pure sine wave power; while with ultra-wide input voltage range and voltage and frequency stabilization function, strong load capacity, can be compatible with the generator etc. advantages, to meet the needs of the load equipment protection in complex grid environment interference caused by UPS to the network environment. Mains technical parameters: ModelKD-1KVAKD-2KVAKD-3KVAKD-4KVAKD-5KVAKD-6KVARated capacity1KVA2KVA3KVA4KVA5KVA6KVAInputVoltage range220VAC±25% (165VAC 275VAC)Frequency range50/60Hz±5%PhaseSingle phase +N+GOutputWaveformPure sine waveVoltage220VAC±1%Frequency50/60Hz±0.05% (battery power)Waveform distortionLinear load <2%,non linear load <5%Power factor≥0.8BatteryBattery typeMaintenance free lead-acid batteryDC voltage48VDC192VDCCut-off voltage41±1VDC164±1VDCFloat charging voltage55VDC220VDCSystemControl modeSPWM pulse width modulation technologyOverload capacityOverload 125%maintain 5mins to bypass, overload 150%maintain 1S to bypassTransfer time0msEfficiency>95%Man-machineinterfaceLCD displayInput, output voltage and frequency, battery voltage, load power, internal temperature, working statusLED indicatorMains power, inverted, battery, bypass, overload, abnormalRS232communication interfaceConnected with computer software:monitoring UPS working status,schedule power on/off UPS,analyze power status,automatically archive history recordRemote monitoringmanagementoptional SNMP remote monitoring card, remote monitoring UPS working status, schedule power on/off UPS, automatically archive history record, send message alarmProtectionSurge protectionIn line with IEEE527 standardsNoise protectionIn line with FCCA standardsAmbientNoise<55dB(1m away to UPS)Operatingtemperature0 40°CRelative humidity20% 90%(no condensing )Operating heightAltitude <2500m(capacity reduce 5% every 500m heighten)UPS net weight50Kg65Kg75Kg62Kg65 Kg70 KgSize ( W*D*H) mm410×200×535480×200×600650×230×580