Ort der Herkunft |
Shanghai China (Mainland) |
Marke |
CNEKE |
Modell-Nummer |
YBN |
1. Model Y---------------------------------------prefabricated type B---------------------------------------substation --------------------------------------structure characteristics P M --------------------------------------design No. --------------------------------------HV switchgear with main switch --------------------------------------HV switchgear with operating mechanism --------------------------------------transformer rated capacity KVA. Our Client List: 2009 Shanghai Expo 2008 Olympic Games Stadium Shanghai Pudong Airport Three Gorges Project Vietnam Song Power Station Korea Pusan the Second Steel Plant Iran Teheran Cement Plant, ran Teheran the Third Chemical Plant Burundi Hydroelectric Station Malaysia Cement Plant Hydroelectric Station 1. General+ YBM, YBP series of prefabricated substation is the combination of the HV electrical apparatus, transformer, and low voltage transformer equipments and therefore is used in the high-rise buildings, residential districts, urban and rural construction, hi-tech development zone, small and medium size enterprise, mine and oil fields and the temporary construction sites to receive and distribute the power. YBM, YBP series of prefabricated substation is complete set, small sized, compacted structure, running safely, easy maintenance, and mobile. And it only takes the 1/10-1/5 of the space of the same capacity of civil construction distribution, and therefore greatly reduces the construction cost. It can be used in the ring net distribution system, double power distribution system or radiator terminal distribution system. It is the new complete set equipment used for rural and urban substation construction and reformation. YBM, YBP series of prefabricated substation is fully in accordance with the standard of SD320-1992 (the technology of Boxes substation) and the standard of GB/T 17467-1998 (HV/LV prefabricated substation). The shell is made of non-metal, composite board or the steel sheet as per the users. 3. Technical parameters Serial No.UnitItemHV electrical apparatusTransformerLV electrical apparatus1Rated voltage UeKV7.2126/0.410/0.40.42Rated capacity SeKVAP: 200 1250M: 50 4003Rated current leA200 630100 30004Rated drop-out currentALoad switch400 630A15 63KAComposite apparatus5Rated short time withstand current (S)KA(xs)20*(2)200 400KVA15*112.5*(4)400KVA30*16Rated withstand current (peak)KA31.550200 400KVA30400KVA637Rated making currentKA31.5508Power frequency withstand voltage 1minKAPhase-earth and phase-phase 3240Oil-immersed:35/5min≤300V:2KV3448Dry-type:28/5min300600V:2.5KV9Lightning impulseKVPhase-earth and phase-phase 607575Isolation fracture:75857510Noise leveldBOil-immersed:55Dry-type:6511Protection degreeIP23D12External dimensionas per the capacity of the transformer