UI2000 Digitale EVG Analyzer

UI2000 Digitale EVG Analyzer

Hangzhou, China
Produktionskapazität:
30 Einstellen / Monat
Hangzhou, China
Firma
86-571-81959205
13486090393
Eric Shi
Kontaktperson

Basisdaten

Ort der Herkunft Zhejiang China (Mainland)
UI2000 Digital Electronic Ballast Analyzer is used to test and analyze the input and output electrical characteristics of electronic ballast.Itmeets to the electronic ballasts in international standards of IEC60929, IEC60969, IEC61000-3-2, GB/T15144-94, GB/T17263-2002. Compared with traditional power frequency measuring instruments (normally, frequency response is less than 10KHz), if the electronic ballast designated to be tested has high frequency feedback but is unreasonably designed, this traditional instruments will encounter following measuring errors: Tested value of electric current is inclined to be small.Tested value of power factor turns to be big (just as generally so-called deceptive high power factor.Test reading fluctuates greatly and display data is unstable.Testing functions of UI2000’s narrow band (frequency response is 45Hz-5kHz ) and broad band solve this problem efficiently, ensuring testing accurateness of electric current and power factor of various electronic ballast. Features: 1. Simultaneously display on 8 windows for input and output parameters to convenient for comparing and analysis. 2. It can be connected with PC for automatic recording the changing of curve. 3. Input and output parameters tested simultaneously within 1 second. 4. According to the electronic ballasts in international standards of IEC60929, IEC60969, IEC61000-3-2,GB/T15144-94, GB/T17263-2002 Input characteristics: 1. Voltage, Current, Power, PF, Hz, Phasicangle. 2. THD (Total Harmonic Distortion) of current and voltage, 0-39th harmonic and harmonic spectrum diagram. 3. The actual waveform of current and voltage and the current waveform phase analysis. 4. The difference of the lamp current in every successive half-cycle analysis etc. 5. Accuracy: ±(0.1% reading + 0.1%range + 1digit) 6. Measures the changing and maximum value of input voltage and current in start-up state Output characteristics: 1. Measure the RMS(Root Mean Square) of Lamp Voltage, Lamp Current, Lamp Power, Oscillating Frequency and Crest Factors. 2. Accuracy for voltage and current: ±2% Power: ±3% 3. Test the peak values and variations of RMS(Root Mean Square) of lamp voltage, lamp voltage, filament current and cathode current from start time to the 5th second. Startup parameters measurement: 1. Measure pre-heat energy and filament pre-heat time, test parameter changing curves of filament voltage, filament current, and filament power from 0 to 5 seconds after startup.

Lieferbedingungen und Verpackung

Leider hat der Verkäufer die Lieferbedingungen nicht angegeben. Für weitere Informationen kontaktieren Sie den Verkäufer.

Zahlungsbedingungen

Telegraphic transfer

Western Union

Фотографии

    Passwortwiederherstellung
    Um Ihr Passwort wiederherzustellen, geben Sie hier Ihre EMail-Adresse ein, mit der Sie sich bei uns registriert haben:
    Der Code zum Zurücksetzen des Passworts wurde an Ihre E-Mail gesendet.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    Es ist ein Fehler aufgetreten. Bitte überprüfen Sie Ihre EMail-Adresse und versuchen Sie es nochmal.
    Ваш новый пароль:

    Name ist leer


    Выберите страну доставки

    Sie haben keine Nachricht geschrieben

    Durch das Anklicken des Buttons "Abschicken" erklären Sie sich einverstanden, daß Ihre Daten zur Bearbeitung Ihres Anliegens verwendet werden. Weitere Informationen und Widerrufshinweise finden Sie in der Dateschutzerklärung.

    Ihre Nachricht wurde versendet!

    Schließen

    1
    Рынок B2B
    Cancel Close
      Mehr zeigen zuklappen
        Regionsuche
        Weltweit
        Категории
          Produktbezeichnung