Ort der Herkunft |
Zhejiang China (Mainland) |
Marke |
DOVOL |
Modell-Nummer |
T1 |
Größe |
L |
Eingangsspannung |
220/380V |
Ausgangsspannung |
0-220/380V |
Ausgangssignals Frequenz |
0-600HZ |
Ausgangsstrom |
13-18A |
Geben |
DC/AC-Wechselrichter |
T1 high performance vector-control Frequency inverter Technical features: 1.perfect protections:over-load,over-current, over-voltage,under-voltage, phase failure, short circuit and leakage protection. 2.multiple control functions:multi-step speed,PID control,3-wire and 2-wire control,up to 8 programmable input ports;applicable for various applications. 3.low rotation speed,high torque. 4.RS485 communication interface. 5.motor parameter auto-tuning function. 6.open loop torque control can realize realTension Control. 7.high start torque,0.5Hz/150%. 8.speed control includes:vector control without PG,V/F control. Aplications: 1.lathe, forging machine,CNC center 2.applications with low speed and high torque Input and output Input voltage range: 380/220V±15% Input frequency range: 47-63Hz Output voltage range: 0rated input volatge Output frequency range: 0-600Hz Peripheral interface programmable digital input: 4 inputs programmable analog input: FV: 010V input; FI: 020mA input open-collector C1: 1 output relay output: 1 output analog output F: 1 output: 010V output Technical performance control mode: vector control without PG, V/F control overload capacity: 150% rated current 60s; 180% rated current 10s starting torque: vector control without PG: 0.5Hz/150% (SVC) Speed Adjusting Range: vector control without PG,1:100 Speed Accuracy: vector control without PG:±0.5% of maximum speed carrier frequency: 1.0K15.0KHz Function features Frequency reference source: digital setting,analog setting,serial communication,multi-step speed,PID,etc.PID control function Multi-steps speed control: 8 steps speed can be set. Traverse control function Non-stop function while instantaneous power failure track the rotation speed,then start: Smoothly start the running motor. Automatic Voltage Regulation (AVR): Automatically keep the output voltage stable when input voltage is fluctuating. Up to 25 fault protections: over current, over voltage, under voltage, over temperature, phase failure, over load etc. Working enviroment Temperature -10 to +40 Humidity Below 90% RH (No condensing) Altitude Below altitude 1000m. when altidude is above 1000m,if the altidude increases every 100m,the rated power of inverter shoud derate 3%; when altidude is above 2000m,if the altidude increases every 100m, the rated power of inverter shoud derate 5%. Others No corrosive and flammable gas, No conductive dust.