Ort der Herkunft |
Shanghai China (Mainland) |
Marke |
KEYNAI |
Modell-Nummer |
S(B)H15/16 |
Phase |
Drei |
Nutzung |
Macht |
Struktur Umdrehungen |
Ringkern |
Over a century, principle of power transformer has not ever been changed, but along with the development and progress of the times. The advanced production facilities are being perfected, the transformer with amorphous alloy core produced by our company adopts new style magneto conductive material, i.e. amorphous alloy core. The no-load loss of this kind of transformer is 80% lower than that of stalloy cored transformer, and no-load current also is 80% lower. It is the most ideal distribution transformer in energy saving at present, especially suitable for the rural power grids and developing districts, where the load factor is rather low. The amorphous alloy cored power transformer has advantages of low no-load loss, energy saving and environment protection, are fully in accordance with our national industrial policy “resource-saving, environmentally-friendly, establish a REEF Society”. The oil immersed transformer also has ability to reduce and eliminate CO, SO and NOX these harmful gases, is titled as “green material” of 21st century. Features of Products 1.The Transformer core is made of amorphous alloy band, no-load loss is 80% lower than that of s9 type transformer and 25% lower than the stipulated value of JB/T10318. 2.Transformer adopts copper foil LV winding to strengthen the bearing capability against short-circuits. 3.The transformer connecting group adopts Dyn 11 to reduce the effect of harmonic wave to power grid and improve power supply quality. 4.Full sealed structure, the oil tank is welded to tank cover tightly, prolong the service life, maintenance-free. 5.The transformer adopts vacuum oiling mode, which fully eliminate blisters from winding, and guarantees stable insulation. 6.Before leaving the factory, each piece of transformer has been experienced full wave lightning impulse test that the peak voltage is 25% higher than that of national standard, thus to make sure that the transformer can run safely and reliably. Technical parameter SH15 – M Rated capacityVoltage combination and tapping rangeLabel of connecting groupLoad current(A)No-load loss(W)On-Load loss(W)Short circuit impedance(%)High-Voltage(KV)Low-Voltage(KV)Scope of regulator(%)306 6.3 10 10.5 11 0.4±5±2x2.5Dyn111.7336004501.343870631.2501040801.160125010017515001250.98518001600.710022002000.712026002500.714030503150.517036504000.520043005000.524051006300.332062004.58000.3380750010000.34501030012500.25301200016000.26301450020000.275017400525000.290020200 SH16 - M ModelVoltage combinationcon-necting groupNo-Load current(A)No-load loss(W)On-Load loss(W)Impe- dance voltage(V) L(mm)H(mm)W(mm)Center of installation base (L2xL1/4-ΦDmm)Weight of oil(kg)Total weight(kg)High-Voltage(KV)High voltage tapping rang (%)Low-Voltage(KV)SH16-M-50/106 6.3 10 10.5 11 (20) ±2×2.5 ±31x2.5 0.4Dyn11 Yyn0 0.93887049501040620400x550/4-Φ14160680SH16-M-100/100.758150010601070770400x660/4-Φ14190890SH16-M-160/100.578220010601150930400x870/4-Φ192501190SH16-M-200/100.590260011101170930550x870/4-Φ192701300SH16-M-250/100.51103050118011801010550x870/4-Φ193001460SH16-M-315/100.41303650118011801010550x870/4-Φ192401400SH16-M-400/100.41604300120011801010550x870/4-Φ192801660SH16-M-500/100.41905150127012001160660x1070/4-Φ193001950SH16-M-630/100.323062004.5145013301240820x1070/4-Φ194802450SH16-M-800/100.32807500152014601380820x1070/4-Φ195202900SH16-M-1000/100.333010300172015101460820x1070/4-Φ196803500SH16-M-1250/100.239012000178516901330820x1070/4-Φ198003980SH16-M-1600/100.247014500188019701380820x1070/4-Φ198505300SH16-M-2000/100.2570174005208019651540820x1070/4-Φ1913106150SH16-M-2500/100.268020200240023501500820x1070/4-Φ1918508200