Rosemount Druckmessumformer 1151

Rosemount Druckmessumformer 1151

Shanghai, China
Produktionskapazität:
1000 Einstellen / Monat
Shanghai, China
Starter
86-21-58754297
Zhuang Chris
Kontaktperson

Basisdaten

Ort der Herkunft United States
Marke Rosemount
Modell-Nummer 1151
With over five million transmitters installed worldwide, the Rosemount 1151 continues to offer industry leading value. Changing customer needs and new technologies have driven product improvements, while advanced manufacturing and testing processes have guaranteed product quality. Even today, the Rosemount 1151 is world-reowned for proven field reliability and longevity. Proven field performance and reliability For over 35 years, the 1151 has provided the process control industry with unsurpassed service and reliability in even the harshest of environments. The lasting customer preference results from a combination of advanced technology, and a tradition of field proven performance. Commitment to continuous improvement Through ongoing focus on continuous improvement, ±0.075% reference accuracy has been accomplished as a result of manufacturing and engineering enhancements. In addition, Smart electronics offer rangeability to 50:1, reducing the number of transmitters to specify, procure, and carry in inventory. A modular design allows interchangeable mechanical and electrical components, providing backward and forward compatibility. Application flexibility The 1151 offers a variety of configurations for differential, gage, absolute and liquid- level measurements including integrated solutions for pressure, level, and flow. High pressure models allow static line pressures up to 4500 psi (310 bar). Multiple wetted materials, as well as alternative fill fluids ensure process compatibility. Smart, analog and low-power electronics are available to meet specific application requirements. PERFORMANCE SPECIFICATIONS (Zero-based calibrated ranges, reference conditions, silicone oil fill, 316 SST isolating diaphragms.) Accuracy Output Code S Ranges 3 through 8, DP and GP transmitters; Ranges 4 through 7, HP transmitters ±0.075% of calibrated span for spans from 1:1 to 10:1 of URL. Between 10:1 and 50:1 of URL. All other ranges and transmitters ±0.25% of calibrated span(1) Output Code S, square root mode Output Codes E, G, L, and M ±0.2% of calibrated span for 1151DP Ranges 3 through 5. All other ranges and transmitters, ±0.25% of calibrated span. Stability Output Code S ±0.1% of URL for 2 years for DP and GP Ranges 3 through 8. (±0.25% for all other ranges and transmitters.) Output Codes E and G ±0.2% of URL for six months for Ranges 3 through 5. (±0.25 for all other ranges.) Output Codes L and M ±0.25% of URL for six months Temperature Effect Output Code S [20 to 185 °F (29 to 85 °C)] For DP and GP transmitter Range 4 through 8; HP transmitter Range 4 through 7: Zero Error = ±0.2% URL per 100 °F (56 °C) Total Error = ±(0.2% URL + 0.18% of calibrated span) per 100 °F; For Range 3, double the stated effects. For other ranges and transmitters follow analog temperature specifications (Output Code E). Output Code E, G, L, and M [20 to 200 °F (29 to 93 °C)] For Ranges 4 through 0 Zero Error = ±0.5% URL per 100 °F. Total Error = ±(0.5% URL + 0.5% of calibrated span) per 100 °F; double the effect for Range 3. Static Pressure Effect DP Transmitters DP Transmitters Zero Error ±0.25% of URL for 2,000 psi (13790 kPa) for Range 4 and 5 or ±0.5% for other ranges, correctable through rezeroing at line pressure. Span Error Correctable to ±0.25% of input reading per 1,000 psi (6895 kPa), or to ±0.5% for Range 3. HP Transmitters Zero Error ±2.0% of URL for 4,500 psi (31027 kPa), correctable through rezeroing at line pressure. Span Error Correctable to ±0.25% of input reading per 1,000 psi (6895 kPa). Vibration Effect 0.05% of URL per g to 200 Hz in any axis Power Supply Effect Output Codes S, E, and G Less than 0.005% of output span per volt Output Codes L, M Output shift of less than 0.05% of URL for a 1 V power supply shift Load Effect Output Codes S, E, and G No load effect other than the change in power supplied to the transmitter. Output Codes L, M Less than 0.05% of URL effect for a change in load from 100k to infinite ohms. Short Circuit Condition (Low Power Only) No damage to the transmitter will result when the output is shorted to common or to power supply positive (limit 12 V). EMI/RFI Effect Output shift of less than 0.1% of span when tested to SAMA PMC 33.1 from 20 to 1000 MHz and for field strengths up to 30 V/m. Mounting Position Effect Zero shift of up to 1 inH2O (0.25 kPa). With liquid level diaphragm in vertical plane, zero shift of up to 1 inH2O (0.25 kPa). With liquid level diaphragm in horizontal plane, zero shift of up to 5 inH2O (1.25 kPa) plus extension length on extended units. All zero shifts can be calibrated out. No effect on span. FUNCTIONAL SPECIFICATIONS Service Liquid, gas, and vapor applications Ranges See Table 2 for ranges. Minimum span equals the upper range limit (URL) divided by rangedown. Rangedown varies with the output code See Table 1. Outputs Code S, Smart 420 mA dc, user selectable for linear or square root output. Digital process variable superimposed on 420 mA signal, available to any host that conforms to the HART® protocol. Code E, Analog 420 mA dc, linear with process pressure Code G, Analog 1050 mA dc, linear with process pressure Code L, Low Power 0.8 to 3.2 V dc, linear with process pressure Code M, Low Power 1 to 5 V dc, linear with process pressure Current Consumption Under Normal Operating Conditions (Low Power Only) Output Code L 1.5 mA dc Output Code M 2.0 mA dc Zero Elevation and Suppression Output Codes S, E, and G Zero elevation and suppression must be such that the lower range value is greater than or equal to the (URL) and the upper range value is less than or equal to the (+URL). The calibrated span must be greater than or equal to the minimum span and less than or equal to the maximum span. Output Code L Zero is adjustable ±10% of URL and span is adjustable from 90 to 100% of URL. Output Code M Zero is adjustable ±50% of URL and span is adjustable from 50 to 100% of URL. Span and Zero Output Code S Span and zero may be accessed with local adjustments or remotely through a HART-compatible Interface. Output Codes E, G, L, and M Span and zero are continuously adjustable. Power Supply External power supply required. Transmitter operates according to the following requirements: Output Codes S, E 12 to 45 V dc with no load Output Code G 30 to 85 V dc with no load Output Code L 5 to 12 V dc Output Code M 8 to 14 V dc.

Lieferbedingungen und Verpackung

Packaging Detail: Regular export cargo container and package up to client's request. Delivery Detail: 20 Days shipped to destination upon order
Hafen: Shanghai (or other southern China port up to client's preference)

Zahlungsbedingungen

Telegraphic transfer

Western Union

Фотографии

    Passwortwiederherstellung
    Um Ihr Passwort wiederherzustellen, geben Sie hier Ihre EMail-Adresse ein, mit der Sie sich bei uns registriert haben:
    Der Code zum Zurücksetzen des Passworts wurde an Ihre E-Mail gesendet.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    Es ist ein Fehler aufgetreten. Bitte überprüfen Sie Ihre EMail-Adresse und versuchen Sie es nochmal.
    Ваш новый пароль:

    Name ist leer


    Выберите страну доставки

    Sie haben keine Nachricht geschrieben

    Durch das Anklicken des Buttons "Abschicken" erklären Sie sich einverstanden, daß Ihre Daten zur Bearbeitung Ihres Anliegens verwendet werden. Weitere Informationen und Widerrufshinweise finden Sie in der Dateschutzerklärung.

    Ihre Nachricht wurde versendet!

    Schließen

    1
    Рынок B2B
    Cancel Close
      Mehr zeigen zuklappen
        Regionsuche
        Weltweit
        Категории
          Produktbezeichnung