Ort der Herkunft |
Shandong China (Mainland) |
Marke |
KEYA |
Modell-Nummer |
115/230RT10AL |
Reversible DC Motor DriveDC Motor Drive 1. Summary MMT-SCR series DC motor controllers are full-wave positive feedback motor controllers and can control motors in bi-directional mode. It provides four-quadrant operation, which can realize positive and reverse torque in two speed directions. 2.Product Features 1. Applicable to permanent-magnet, separate excitation DC motor 2. Large torque for low-speed start-up. 3. The mechanical characteristics of hardness, static error rate of 1%. 4. A wide speed-regulating range (0 - max). 5. A rapid dynamic response process.(adjustable) 6. Automatic and smooth transition process during acceleration or deceleration. 7. Current setting and current limiting protection (If the preset current value is exceeded, the driver stops output automatically.) 8. Setting functions of positive and opposite soft start/soft stop time (adjustable) 9. Self-locked function. 10. Positive rotation and reverse rotation are selectable. 11. Dual closed loop PI adjustment (Current and Voltage),The closed-loop feedback is selectable. 12. The speed control mode and torque control mode are selectable. 13. The inertial gliding stop and braking stop are selectable. 14. The input voltage and output voltage are selectable. 3.Main Parameters 1. AC Input Voltage (VAC±10% 50/60HZ) ------------------------------------------115V/230V 2. AC Frequency (Hz) --------------------------------------------------------------------50/60 3. Amarture voltage range 115VAC line (VDC) -------------------------------------0- ±9 0 4. Amarture voltage range 230VAC line (VDC) -------------------------------------0- ±9 0 /0-±180 5. Excitation voltage at 115VAC line (VDC) -----------------------------------------100/50 6. Excitation voltage at 230 VAC line (VDC) ----------------------------------------200/100 7. Maximum bearing capacity (% two minutes) ------------------------------------150 8. Operation range of indoor temperature (degree) ------------------------------------- 0-50 9. Speed range in open loop (ratio) --------------------------------------------------- 50:1 10. Speed range in closed loop (ratio) ------------------------------------------------ 80:1 11. Regulation of armature feedback loading (% basic speed) ----------------- ±1 12. Regulation of closed loop feedback (% rated speed) ------------------------ ±1 13. Adjustment of line of alternating current (% basic speed) ------------------ ±0.5 14. Current range (A DC) -----------------------------------------------------------10/15 15. Forward/reverse speed accelerating scope (s) --------------------------0.1- 15 16. Dead zone range (% basic speed) ------------------------------------------0 -±5 17. Range of maximum speed regulation of potentiometer (% basic speed) -------- 55- 110 18. Compensation range in 110VAC line (VDC @ full load) ------------------------------ 0-20 19. IR compensation range in 220VAC (VDC @ full load) --------------------------------0-40 20. Range of forward CL(FCL) and reverse CL(RCL) (% range setting)---------------0-150 21. Volt range changing with the input voltage(VDC)--------------------------------0-±10/0±15 22. Range of voltage with input (% basic speed)------------------------------- ±0.5 23. Ambient Humidity:Relative Humidity≤80RH.(Below dew point)