Display-Typ |
analoge und digitale |
Phase |
Einphasig |
Ort der Herkunft |
Guangdong China (Mainland) |
Marke |
Calin |
Modell-Nummer |
DDS160E |
Energiemessbereiche |
From 0.7 to 1.2Un |
Genauigkeitsklasse |
Class 1.0 |
Ausgangsspannung |
220 V |
Betriebstemperatur |
-25℃to+70℃ |
Abmessungen |
165mm* 110mm *60mm |
Electricity meter,Electricity meter parts,electricity meter kwh General DDS160E single-phase electronic static watt-hour meter is serves as a remote unit in the AMR(Automatic Meter Reading)System, which adopts advanced microelectronics and PLC(Power Line Communication) technology. It can measure active energy of single-phase AC@50Hz. Receiving and transmitting data over the power lines to a central unit-Concentrator, The performance is comfort to IEC 61036:1996 standard. Key Featuresl Measuring AC single-phase bi-directional active energy in wide measurement range, low power consumption and high reliability. l 8 digits 0.01kWh LCD Display. l LED indicator light during power off. l Soft Spread Spectrum Technology is chosen to guarantee the accuracy and reliability of transmitted data over the full distance of the power line. l Automatic relay between meters. l Remote disconnection and reconnection controlled (with the switch accessory). l Power theft detection. l Small physical dimensions. Simple and fast installation. Working PrincipleAs shown in Figure 1, an energy metering IC is adopted (the area inside the broken line). Input Sensor sampling load current and line voltage signal and input to the energy metering IC, which includes a multiplier and a V/F converter. Then output energy pulse signal to IC group for energy consumption counts, LCD display and testing output. The data is transmitted over the power line. The status of the switch is detected by the IC group to realize the remote power disconnection and reconnection. Technical Specifications Class IndexClass 1Reference voltage Un220 VOperating voltage rangeFrom 0.7 to 1.2UnReference current Ib(Imax)10(80) AStarting current0.4%IbMeter constant640 imp/kWhReference frequency50 HzPower consumptionVoltage circuit ≤1.5W and 5VACurrent circuit ≤1.0VAData Retention after power supply failure30 yearsData transmit distance3 km over main power lineOperating temperature range-25°c to +70°cStorage temperature range-45°c to +70°cRelative humidity95%Size165mm × 110mm × 60mmWeight0.72kg Transport and Storage Condition The meters in transport and storage condition should not suffer from violent shock. Place the meter carefully according to the 'up' & 'moistureproof' sign on the package box. Required storage condition: temperature at -45°c to 70°c, relative humidity is not exceeding 95%, without corrosive gas in the air. Electricity meter,Electricity meter parts,electricity meter kwh