Metallgekapselte Niederspannungs-Schaltanlagen

Metallgekapselte Niederspannungs-Schaltanlagen

original-Preis: 10 000 USD
Shanghai, China
Produktionskapazität:
500 Einstellen / Monat
Shanghai, China
Starter
86-21-33521117
Brian Chueng
Kontaktperson

Basisdaten

Ort der Herkunft Shanghai China (Mainland)
Marke CHFE
Modell-Nummer GGD
Standards GB7251.1 Low-voltage switchgear assemblies IEC60439 Low-voltage switchgear and controlgear assemblies Service condition 1. Ambient temperature: -5'C +40'C. Average temperature in 24 hours <= 35'C. 2. Altitude: <=2000m. 3. Air humidity at 40'C <=50%. Higher humidity at lower temperature is permitted. Occasional condensation due to temperature variation should be considered. 4. No excessive vibration. 5. No corrosion to electric elements. Special condition subject to users. Features and Benefits 1.The optimized footprint uses smaller section sizes when possible. Sections are provided in 22", 30" or 38" widths.2.Breaker compartment doors have no ventilation openings, thus protecting operators from hot ionized gases vented by the breaker during circuit interruption.3.A superior bus system offers different levels of protection. Insulated and isolated bus makes maintenance procedures touch friendly to reduce the risk of arc flash.4.True closed-door drawout construction is standard with all GGD equipment. The breaker compartment doors remain stationary and closed while the breaker is racked out from the connect position, through test, to the disconnect position. Doors are secured with rugged 1/4-turn latches.5.An easy-to-read metal instrument panel above each circuit breaker holds a variety of control circuit devices, including the RELT switch.6.Each circuit breaker is located in a completely enclosed ventilated compartment with grounded steel barriers to minimize the possibility of fault communication between compartments.7.Optional safety shutters protect operators from accidental contact with live conductors when the breaker is withdrawn.8.Easy access to equipment compartments simplifies maintenance of the breaker cubicle and control circuit elements as well as inspection of the bolted bus connections.9.The conduit entrance area meets NEC requirements. Extended depth frame options are available in 7" and 14“ sizes for applications requiring additional cable space. The section width also can be increased for additional cable space.10.A rail-mounted hoist on top of the switchgear provides the means for installing and removing breakers from the equipment. This is a standard feature on NEMA 3R outdoor walk-in construction and optional on indoor construction.11.Control wires run between compartments in steel riser channels. Customer terminal blocks are located in metal-enclosed wire troughs in the rear cable area. Intercubicle wiring is run in a wireway on top of the switchgear, where interconnection terminal blocks are located.12.All circuit breakers are equipped with rollers and a guidebar to provide easy and accurate drawout operation.13.An optional remote racking device reduces the risk of the arc flash hazard by allowing the operator or electrician to move the breaker anywhere between the DISCONNECT and CONNECT positions from outside the arc flash boundary.14.Optional infrared (IR) scanning windows can be installed in the switchgear rear covers to facilitate the use of IR cameras for thermally scanning cable terminations.15.GGD switchgear can be expanded easily to handle increased loading and system changes. Specify a requirement for a fully equipped future breaker to obtain a cubicle that has been set up for additional breaker installation, or add vertical sections without modifications or the use of transition sections.16.An array of safety interlock and padlocking features are available to accommodate any type of lockout-tagout procedure a customer may have.17.Optional Power Management: With the proper devices, facility power can be tracked and controlled.GGD Metal-enclosed Low Voltage SwitchgearModelRated voltage (V)Rated current (A)Rated short-circuit breaking current (kA)Rated short time withstand current (1s) (kA)Rated peak withstand current (kA)GGD-1000-15380A1000151530B600(630)C400GGD-1600-30A1500(1600)303063B1000C600GGD-3150-50A31505050105B2500C2000

Lieferbedingungen und Verpackung

Packaging Detail: Wooden case Delivery Detail: 25 days
Hafen: Shanghai

Zahlungsbedingungen

Letter of credit

Telegraphic transfer

Фотографии

    Passwortwiederherstellung
    Um Ihr Passwort wiederherzustellen, geben Sie hier Ihre EMail-Adresse ein, mit der Sie sich bei uns registriert haben:
    Der Code zum Zurücksetzen des Passworts wurde an Ihre E-Mail gesendet.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    Es ist ein Fehler aufgetreten. Bitte überprüfen Sie Ihre EMail-Adresse und versuchen Sie es nochmal.
    Ваш новый пароль:

    Name ist leer


    Выберите страну доставки

    Sie haben keine Nachricht geschrieben

    Durch das Anklicken des Buttons "Abschicken" erklären Sie sich einverstanden, daß Ihre Daten zur Bearbeitung Ihres Anliegens verwendet werden. Weitere Informationen und Widerrufshinweise finden Sie in der Dateschutzerklärung.

    Ihre Nachricht wurde versendet!

    Schließen

    1
    Рынок B2B
    Cancel Close
      Mehr zeigen zuklappen
        Regionsuche
        Weltweit
        Категории
          Produktbezeichnung