Magnetventil für Ammoniak und Freon, Wasser-Öl-ga

Magnetventil für Ammoniak und Freon, Wasser-Öl-ga

original-Preis: 20,00 USD
Songjiang, China
Produktionskapazität:
500 Stück / Tag
Songjiang, China
Starter
86-21-67728816-825
Leo Chen
Kontaktperson

Basisdaten

Port-Größe 3mm 3.5mm 4mm
Ort der Herkunft Shanghai China (Mainland)
Modell-Nummer ADF
Marke STF
Standard ja
Struktur Pilot
Druck Hochdruck
Energie Magnetspule
Material Edelstahl
solenoid valve for ammonia and freon Features: 1.Coil of this type is hermetic by plastic.It features moisture proof,anti-viberation,and anti-corrosive.All parts are made by stainless steel.It can be used for ammonia and Freon refrigerating system,pneumatic hydraulic and water supply system. 2. suitable for HFC,HCFC refrigerants and Ammonia; clean water ;</=viscosity machine oil 3.Coil type: AC:24V 36V 110V 220V DC: 12V 24V 110V 200V 4:opening pressure diff: AC: 0.05----21bar DC:0.05-17bar 5:Max working pressure :30bar 6:working range:---25°Ccentigrade to 100°C Operating principle ADF series solenoid valve is pilot type valve.When energized the coil,it lead a magnet and pick up plug,open the small orifice,course to pressure in upside of valve reduced.So the pres sure difference happen both side of diaphragm. The pressure difference lift diaphragm to open the main Orifice.When main orifice open,dia phragm shouldnt drop even if pressure difference both side of diaphragm exist too,because of flow inertia function.When coil deenergized,plug drop to close small orifice because of reset spring. Media flow to upside of valve through throttle orifice.Then balance pressure both side of diaphragm,so diaphragm return to close the mail valve. Installation: 1.The valve must install in horizontal pipe line under vertical position. The flow direction must be meet the arrow direction in valve boby. 2.Installing position should be low viberation. 3.Must install filter before solenoid valve in order to prevent block throttle port and lead to no function. 4.The coil input power must meet rated input power showed on the label. 5.System operating pressure must be meet open valve pertormance. 6.Departure coil from valve when en ergized in coil is limited in order to avoid damage the coil. 7.According to valve with manual function.It must turn manual bar to open the vaNe bemre doing system air tightness, in order to avoid to damage diaphragm.

Lieferbedingungen und Verpackung

Packaging Detail: normal package Delivery Detail: within 15 days
Hafen: FOBshanghai

Zahlungsbedingungen

Telegraphic transfer

Фотографии

    Passwortwiederherstellung
    Um Ihr Passwort wiederherzustellen, geben Sie hier Ihre EMail-Adresse ein, mit der Sie sich bei uns registriert haben:
    Der Code zum Zurücksetzen des Passworts wurde an Ihre E-Mail gesendet.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    Es ist ein Fehler aufgetreten. Bitte überprüfen Sie Ihre EMail-Adresse und versuchen Sie es nochmal.
    Ваш новый пароль:

    Name ist leer


    Выберите страну доставки

    Sie haben keine Nachricht geschrieben

    Durch das Anklicken des Buttons "Abschicken" erklären Sie sich einverstanden, daß Ihre Daten zur Bearbeitung Ihres Anliegens verwendet werden. Weitere Informationen und Widerrufshinweise finden Sie in der Dateschutzerklärung.

    Ihre Nachricht wurde versendet!

    Schließen

    1
    Рынок B2B
    Cancel Close
      Mehr zeigen zuklappen
        Regionsuche
        Weltweit
        Категории
          Produktbezeichnung