Ort der Herkunft |
Guangdong China (Mainland) |
Marke |
Yada |
Modell-Nummer |
YD2200 |
Genauigkeitsklasse |
0.2 |
Betriebstemperatur |
-15~+55 |
Abmessungen |
96*96mm |
Introduction YD2200 is a powerful Multi-function Power Meter to measure and display all the parameters as well as harmonics content, with 4 expansion plug-ins: RS485 comms, digital input/output, energy pulse, and DC4-20mA output, so as to meet all kinds of demands. Measurement Voltage (Ph-Ph/Ph-N) Current (Ph-Ph/Ph-N) Active Power Reactive Power Apparent Power Frequency Power Factor Harmonics Total harmonics content of voltage (Ph-Ph) Total harmonics content of current (Ph-Ph) 3rd-19th harmonics content of voltage (Ph-Ph) (RS485 output) 3rd-19th harmonics content of current (Ph-Ph) (RS485 output Maximum Value Max. instantaneous value (V, I) Max. instantaneous value (±Kwh, ±Kvah) Max. instantaneous value (S) Computation Energy Pulse(Expansion) Import active energy YM-E2 provides 2 energy pulse Export active energy outputs. Import reactive energy Active/Reactive Energy Pulse output Export reactive energy 0.1-100000kWh/one pulse (option) Dry contact output (1A*100V). Pulse Output (option) One pulse output, active energy/reactive energy Pulse constant: 5000/kWh. Photocoupler output(0.1A*30V). Measuring Range 30-600V 0-6A 45-65Hz Accuracy Frequency: 0.1% Voltage: 0.2%±0.1V Current: 0.2%±0.001A Power: 0.5%±0.4W Power Factor0: .5%±0.001 -1-0-1 Energy: 1.0% Display Green back-lit LCD,5 displays.6 operational keys. Communication Expansion Module YM-485 provides RS-485 port,ModBus-RTU protocol; 32(128) meters are connected as a network. Data Acquisition (Expansion) Each YM-K2 module collects 2 routs of dry contacts and accumulates the counting. Control (Expansion) Each YM-K2 provides 2 relay outputs, which can be controlled by communication, remote control or by some measured parameter. Analog Output (Expansion) Each YM-A20 provides 2 DC4-20mA outputs, corresponding to some parameter. System 3P4W 3P4W BAL 3P3W 3P3W BAL 1P2W 1P3W Programmable Measuring System :3P4W/3P3W etc. Transformation Ratio:PT; CT Comms.Add. (1-247);Baud rate (1200-19200);Parity bit (N/E/O) RTC:Year/Month/Day/Hour/Minute/Second Energy:Reset Dimension Mounting Panel:96x96mm Thickness:20mm Depth:52mm(without module) ; 80mm with module Mounting Panel Mounting Hole :92x92mm Power Supply (AC/DC) A85-265V or DC85 330V (Standard) DC18-90V (Optional) Power Consumption) :< 4VA Working Conditions Temp.:-15-55 Humid: 20-95% (without condensation)