Nutzung |
Industrie |
Theorie |
Temperatur Controller |
Ort der Herkunft |
Zhejiang China (Mainland) |
Marke |
CNAOB |
DIGITAL TEMPERATURE CONTROLLER WITH UNIVERSAL INPUT relay output SSR output Thermostat Size: A:96×96mm D:72×72mm E:48×96mm F:96×48mm G:48×48mm H:160×80mm S:80×160mm21 inputs: K,S,R,T,E,J,B,N,WRe3-WRe25, Cu50, Pt100, DC 0 20mV, 0 60mV, 0 100mV, 0 1V, 0 5V, 1 5V, DC 0 10mA, 0 20mA, 4 20mA, 30 350 Ω 21 signals including signals of thermocouple, resistance thermometer detector (RTD), direct voltage, direct current, resistance can be input freely Modules L2, L4, G, W1, X, X5, K1, K5/K7, S, U24, U12, U10, U5 can be addedModule name Module Code Technical parameters Output module of relay contact switch(Alarm output) L2 Normally closed + normally open (absorbed by varistor), 30VDC/1A, 250VAC/1A Output module of relay contact switch(control output) L4 Normally closed + normally open (absorbed by varistor), 30VDC/5A,250VAC/5A Solid-state relay drive voltage output G Output voltage:DC12V/25mA, with function of output short-circuit protection Output module of non-contacting thyristor switch W1 Normally open, 100-240VAC/0.2A (consistent), 2A (20ms,instantaneous, repeat circle >5s), recommended for controlling AC contactor of 100A below Output module of direct current X Optoelectronic isolation , for controlling or transmitting (0.5 level) output, output voltage> 10.5VDC, freely changeable among 0-10mA, 0-20mA and 4-20mA, resolution no less than 0.1% Output module of direct voltage X5 Optoelectronic isolation , For controlling or transmitting (0.5 level) output, output impedance: 250Ω, freely changeable between 0-5V and 1-5V, resolution no less than 0.1% Output module of single-phase thyristor zero-crossing trigger signal K1 100-380VAC, adaptive electric network frequency, capable of triggering 5-500A TRIAC or 2 SCRs in inverse parallel connection or thyristor power module Output module of single-phase thyristor phase-shifting trigger signal K5/K7 K5:220-380VAC / K7:100-220VAC, adaptive electric network frequency, capable of triggering 5-500A TRIAC or 2 SCRs in inverse parallel connection or thyristor power module RS485 COMMUNICATION INTERFACE S Optoelectronic isolation DC 24V feeding voltage output module U24 Power supply isolation,24V±5%,up to 50mA DC 12V feeding voltage output module U12 Power supply isolation,12V±5%,up to 50mA DC 10V feeding voltage output module U10 Power supply isolation,10V±5%,up to 50mA DC 5V feeding voltage output module U5 Power supply isolation,5V±5%,up to 50mA