DIGITAL TEMPERATURE CONTROLLERWITH RS485 temperature regulator Size: A:96×96mm D:72×72mm E:48×96mm F:96×48mm G:48×48mm H:160×80mm S:80×160mm 21 inputs: K,S,R,T,E,J,B,N,WRe3-WRe25, Cu50, Pt100, DC 0 20mV, 0 60mV, 0 100mV, 0 1V, 0 5V, 1 5V, DC 0 10mA, 0 20mA, 4 20mA, 30 350 Ω 21 signals including signals of thermocouple, resistance thermometer detector (RTD), direct voltage, direct current, resistance can be input freely Modules L2, L4, G, W1, X, X5, K1, K5/K7, S, U24, U12, U10, U5 can be added Module name Module Code Technical parameters Output module of relay contact switch(Alarm output) L2 Normally closed + normally open (absorbed by varistor), 30VDC/1A, 250VAC/1A Output module of relay contact switch(control output) L4 Normally closed + normally open (absorbed by varistor), 30VDC/5A,250VAC/5A Solid-state relay drive voltage output G Output voltage:DC12V/25mA, with function of output short-circuit protection Output module of non-contacting thyristor switch W1 Normally open, 100-240VAC/0.2A (consistent), 2A (20ms,instantaneous, repeat circle >5s), recommended for controlling AC contactor of 100A below Output module of direct current X Optoelectronic isolation , for controlling or transmitting (0.5 level) output, output voltage> 10.5VDC, freely changeable among 0-10mA, 0-20mA and 4-20mA, resolution no less than 0.1% Output module of direct voltage X5 Optoelectronic isolation , For controlling or transmitting (0.5 level) output, output impedance: 250Ω, freely changeable between 0-5V and 1-5V, resolution no less than 0.1% Output module of single-phase thyristor zero-crossing trigger signal K1 100-380VAC, adaptive electric network frequency, capable of triggering 5-500A TRIAC or 2 SCRs in inverse parallel connection or thyristor power module Output module of single-phase thyristor phase-shifting trigger signal K5/K7 K5:220-380VAC / K7:100-220VAC, adaptive electric network frequency, capable of triggering 5-500A TRIAC or 2 SCRs in inverse parallel connection or thyristor power module RS485 COMMUNICATION INTERFACE S Optoelectronic isolation DC 24V feeding voltage output module U24 Power supply isolation,24V±5%,up to 50mA DC 12V feeding voltage output module U12 Power supply isolation,12V±5%,up to 50mA DC 10V feeding voltage output module U10 Power supply isolation,10V±5%,up to 50mA DC 5V feeding voltage output module U5 Power supply isolation,5V±5%,up to 50mA

Lieferbedingungen und Verpackung

Leider hat der Verkäufer die Lieferbedingungen nicht angegeben. Für weitere Informationen kontaktieren Sie den Verkäufer.

Zahlungsbedingungen

Telegraphic transfer

Фотографии

    Passwortwiederherstellung
    Um Ihr Passwort wiederherzustellen, geben Sie hier Ihre EMail-Adresse ein, mit der Sie sich bei uns registriert haben:
    Der Code zum Zurücksetzen des Passworts wurde an Ihre E-Mail gesendet.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    Es ist ein Fehler aufgetreten. Bitte überprüfen Sie Ihre EMail-Adresse und versuchen Sie es nochmal.
    Ваш новый пароль:

    Name ist leer


    Выберите страну доставки

    Sie haben keine Nachricht geschrieben

    Durch das Anklicken des Buttons "Abschicken" erklären Sie sich einverstanden, daß Ihre Daten zur Bearbeitung Ihres Anliegens verwendet werden. Weitere Informationen und Widerrufshinweise finden Sie in der Dateschutzerklärung.

    Ihre Nachricht wurde versendet!

    Schließen

    1
    Рынок B2B
    Cancel Close
      Mehr zeigen zuklappen
        Regionsuche
        Weltweit
        Категории
          Produktbezeichnung