DALI LICHTSTEUERSYSTEME

DALI LICHTSTEUERSYSTEME

original-Preis: 45,00 USD
Shenzhen, China
Produktionskapazität:
10000 Stück / Monat
Shenzhen, China
Firma
86-755-29128922
29128823
2912893
JOHN TAM
Kontaktperson

Basisdaten

Ort der Herkunft Guangdong China (Mainland)
Marke DALI
Modell-Nummer DALI CS
Digital Addressable Lighting Interface (DALI) is a technical standard for network-based systems that control lighting in buildings. It was established as a successor for 0-10 V lighting control systems, and as an open standard alternative to Digital Signal Interface (DSI), on which it is based. The DALI standard, which is specified in the IEC 60929 standard for fluorescent lamp ballasts, encompasses the communications protocol and electrical interface for lighting control networks. A DALI network consists of a controller and one or more lighting devices (e.g., electrical ballasts and dimmers) that have DALI interfaces. The controller can monitor and control each light by means of a bi-directional data exchange. The DALI protocol permits devices to be individually addressed and it also incorporates Group and Scene broadcast messages to simultaneously address multiple devices (e.g., "Group 1 go to 100%" or "Recall Scene 1"). Each lighting device is assigned a unique static address in the numeric range 0 to 63, making possible up to 64 devices in a standalone system. Alternatively, DALI can be used as a subsystem via DALI gateways to address more than 64 devices. Data is transferred between controller and devices at 1200 baud. DALI requires a single pair of wires to form the bus for communication to all devices on a single DALI network. The network can be arranged in a "daisy-chain", "star", or "T" topology, or any combination of these. The DALI System is not classified as SELV (Separated Extra Low Voltage) and therefore may be run next to the mains cables or within a multi-core cable that includes mains power. The DALI signal has a high signal to noise ratio which enables reliable communications in the presence of a large amount of electrical noise. DALI employs Manchester encoding so that devices can be wired without regard for polarity. The network cable is required to be mains-rated, with 600v isolation and at least a 1mm cross-section, with a maximum drop of two volts along the cable. Earlier generations of DALI devices stored configuration data in EEPROM, which was problematic due to the limited number of write cycles supported by EEPROMs. In current generations of DALI devices, RAM is used in preference to EEPROM during normal operation, which significantly reduces the number of EEPROM writes and thus extends their lifetimes. This use of RAM, however, is patented and therefore mandates payment of a license fee.

Lieferbedingungen und Verpackung

Packaging Detail: cartons Delivery Detail: 10-20 days after receiving the deposit
Hafen: SHENZHEN

Zahlungsbedingungen

Telegraphic transfer

Western Union

Фотографии

    Passwortwiederherstellung
    Um Ihr Passwort wiederherzustellen, geben Sie hier Ihre EMail-Adresse ein, mit der Sie sich bei uns registriert haben:
    Der Code zum Zurücksetzen des Passworts wurde an Ihre E-Mail gesendet.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    Es ist ein Fehler aufgetreten. Bitte überprüfen Sie Ihre EMail-Adresse und versuchen Sie es nochmal.
    Ваш новый пароль:

    Name ist leer


    Выберите страну доставки

    Sie haben keine Nachricht geschrieben

    Durch das Anklicken des Buttons "Abschicken" erklären Sie sich einverstanden, daß Ihre Daten zur Bearbeitung Ihres Anliegens verwendet werden. Weitere Informationen und Widerrufshinweise finden Sie in der Dateschutzerklärung.

    Ihre Nachricht wurde versendet!

    Schließen

    1
    Рынок B2B
    Cancel Close
      Mehr zeigen zuklappen
        Regionsuche
        Weltweit
        Категории
          Produktbezeichnung