Ort der Herkunft |
Guangdong China (Mainland) |
Marke |
Cummins+Stamford/Marathon |
Modell-Nummer |
SFJ300K |
Geschwindigkeit |
1500 r/min |
Frequenz |
50 Hz |
Nennleistung |
331 KVA |
Nennspannung |
220V-380V/400V |
Bemessungsstrom |
570 amps |
Ausgangstyp |
Dreiphasenstrom |
Cummins Diesel generator set Model: SFJ300K Frequency : 50Hz Continuous power265kw(331kva)Output voltage380/440V Standby power300kw(375kva)Rate Speed1500r/min Payment : 30% deposit Payment should be T/T or cash in advance. Delivery time: 30 days after received total payment by T/T or cash Commercial Terms : Our company reserves the rights not to tell any change in specifications, and our prices are valid for a period of ten days from the date of the quote Power factorCOSΦ=0.8lagging Start modeElectric Noise level of generator set :70-80dB Packing dimension3750*1500*1850 MML*W*H Fuel consumption:72L/H Weight3790Kg Rated currency(amps)570 ProtectionLow oil-pressure, High water temperature, Over-speed, Over-current. Technical parameters of Gen-Set: Technical parameters of Alternator: Brand:Stamford Power260KW(325KVA) ModelHCI444ES Original:China Protection:IP21 Rated voltage:380/430 V Frequencyfluctuation≤±0.5 % Frequency regulation≤±0.5 %stable Voltage distortion4%Voltage controlAVR Technical parameters of Control Panel: Brand:UPWIN 2210 Start or Stop Generator set manually/ AutomaticallyGenerator over/under frequency protection Open controller output can be defined as Pre-heat/Idle output Generator over/under/unbalance voltage Protection High Coolant temperature protectionOver speed protection Low Oil pressure protectionOver speed protection Over load protectionAvailable for remote control Noteindicate this function depend on the set points of the controller in field *Standard Accessories* 1. Accessories. The standard accessories Single-bearing generator again drops. IP21. Insulation H Radiator for 50 ambient temperature and double-deck cooling The Electric start and 24v charger Regulator Standard air filter Automatic control panel Storage battery Switch for out-wire Steel base-frame against vibration Soft pipe for fuel and handle for lube going-out Operation manual Plastic packing 2. Testing conditions. Standard Air Intake Temperature 25ºC Air Intake Pressure 100kpa Standard Light Diesel 0# or 10# Light diesel Fuel Intake Temperature 40ºC Air Intake Restriction 254mmHg Exhaust Back Pressure 76mmHg Lubricant Oil 15W40-CF4 Upgrade 3. Operation of Cummins Diesel generator set. Continuous power: operate continuously for 24h in a day. 10% overload for An hour is allowed in a 12 hours. Standby power: this is used only when the civil power is off. Overload is not allowed. *Optional Accessories* It is necessary to pay additional if you need these accessories as follows: ATS (Automatic transfer switch) ATS is such a system that can exert the function automatically by transferring two circuits to recover power supply while powering off, in stead of manual work. MCCB (Breaker) Battery charger