CA-2100C Tray Mounted Gas Leak Detector Features: 1. Advanced MPU technology2. Max. capacity of system: 2 channels3. Work in patrol type4.Standard transmission signal of 4-20mA: PositiveTerminal,NegativeTerminal,Signal Line IO5. Four groups of 8-segment LCD display the gas concentration6. Two levels alarming: The first level: 15%LEL (adjustable 10%-25%); the second level: 50 %LEL ( adjustable 26%-99%7. Each level alarming output relay switch signal dependently8. Every alarming output DC24V pulse signal 9. Able to return to zero, 10. Should use with our fixed probe (CA-217A-D) Specifications: Working Method Auto Patrol Output Power DC12V500mA (Supply Power to Detector) Communication 4 20mA Standard Signal Working Power AC220V/50Hz Transmission Distance ≤ 1000 m Alarming Function Two Level Alarm, Alarm Point can be set up Sampling Rate <4 road/second Alarming Sound System Capacity 2 Line Display Method Digital Tube Rotational Display Display Error +- 5% Working Environment: Tem -100C +500C Hum 300C +950C Weight About 1.5 Kg Dimension 260X80X160 mm Product Performance Standards: GB16808-1997GB16808-2008OEM, ODM are welcome