Modell-Nummer YH5W
Main technique parameters: Type: YH1.5W-0.28/1.3 1) The arrester's rated voltage (virtual value): 0.28kV 2) The constant operation voltage (virtual value): 0.24KV 3) The DC reference voltage (Ulm A) no less than: 0.6KV 4) The biggest remain voltage (climax value): a) Under steep-wave surge current: b) Under thunder lighting surge current:: 1.3kV c) Under operation surge current: 5) 2000μs square wave current (climax value): 75A 6) 4/10μs surge current (climax value): 25KA 7) The biggest leakage current under 0.75DC reference voltage: 50μA Type: YH5WS-3.8/15 1) The arrester's rated voltage (virtual value): 3.8KV 2) The constant operation voltage (virtual value): 2.0KV 3) The DC reference voltage (Ulm A) no less than: 7.5KV 4) The biggest remain voltage (climax value): a) Under steep-wave surge current: 17.3KV b) Under thunder lighting surge current:: 15.0kV c) Under operation surge current:12.8KV 5) 2000μs square wave current (climax value): 75A 6) 4/10μs surge current (climax value): 40KA 7) The biggest leakage current under 0.75DC reference voltage: 50μA Type: YH5WZ-3.8/13.5 1) The arrester's rated voltage (virtual value): 3.8KV 2) The constant operation voltage (virtual value): 2.0KV 3) The DC reference voltage (Ulm A) no less than: 7.2kV 4) The biggest remain voltage (climax value): a) Under steep-wave surge current: 15.5KV b) Under thunder lighting surge current:: 13.5kV c) Under operation surge current:11.5KV 5) 2000μs square wave current (climax value): 200A 6) 4/10μs surge current (climax value): 65KA 7) The biggest leakage current under 0.75DC reference voltage: 50μA Type: YH5WS-17/50 1) The arrester's rated voltage (virtual value): 17KV 2) The constant operation voltage (virtual value): 13.6KV 3) The DC reference voltage (Ulm A) no less than: 25KV 4) The biggest remain voltage (climax value): a) Under steep-wave surge current: 57.5KV b) Under thunder lighting surge current:: 50KV c) Under operation surge current:42.5KV 5) 2000μs square wave current (climax value): 75A 6) 4/10μs surge current (climax value): 40KA 7) The biggest leakage current under 0.75DC reference voltage: 50μA Type: YH5WS-51/134 1) The arrester's rated voltage (virtual value): 51KV 2) The constant operation voltage (virtual value): 40.8KV 3) The DC reference voltage (Ulm A) no less than: 73KV 4) The biggest remain voltage (climax value): a) Under steep-wave surge current: b) Under thunder lighting surge current:: 134KV c) Under operation surge current:105KV 5) 2000μs square wave current (climax value): 400A 6) 4/10μs surge current (climax value): 65KA 7) The biggest leakage current under 0.75DC reference voltage: 50μA

Lieferbedingungen und Verpackung

Packaging Detail: in carton Delivery Detail: 30 days

Zahlungsbedingungen

Letter of credit

Telegraphic transfer

Фотографии

    Passwortwiederherstellung
    Um Ihr Passwort wiederherzustellen, geben Sie hier Ihre EMail-Adresse ein, mit der Sie sich bei uns registriert haben:
    Der Code zum Zurücksetzen des Passworts wurde an Ihre E-Mail gesendet.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    Es ist ein Fehler aufgetreten. Bitte überprüfen Sie Ihre EMail-Adresse und versuchen Sie es nochmal.
    Ваш новый пароль:

    Name ist leer


    Выберите страну доставки

    Sie haben keine Nachricht geschrieben

    Durch das Anklicken des Buttons "Abschicken" erklären Sie sich einverstanden, daß Ihre Daten zur Bearbeitung Ihres Anliegens verwendet werden. Weitere Informationen und Widerrufshinweise finden Sie in der Dateschutzerklärung.

    Ihre Nachricht wurde versendet!

    Schließen

    1
    Рынок B2B
    Cancel Close
      Mehr zeigen zuklappen
        Regionsuche
        Weltweit
        Категории
          Produktbezeichnung