Ort der Herkunft |
Zhejiang China (Mainland) |
Marke |
CH |
Modell-Nummer |
SP-3800 Series |
Indrouction Atomic Absorption Spectrophotometer SP-3800 Series is an Atomic Absorption Spectrophotometer with many domestic and international advance technologies Intelligent Straylight measure and correction technology(patent). We developed PC information processing technology, Automatic measurement and straylight dynamic deducted without any reverence materials and increment cost. It improved instrument's optical precision,linear range and background correction effectively. Original Optical Noice RoductionWe developed optical noise reduction technology, which combined opt i cal component UV enhancement technology. It improved instrument's optical performance,linear range and enhanced background correction.Interval lamp control (patent)We developed interal lamp control technology. It makes normal hallow cathode lamps self-absorption back ground correction possible without and influence to instrument's stablity. Meanwhile, it will prolong working like of the lamp. The cost of normal hallow cathode lamp is only about one-tenth of special lamp. Original "Hg lamp-reagent" gradient measurementWe developed "Hg lamp-reagent" gradient measurement technology. we established an exact mathematical model to estimate "double beam linear and balance" specification. This technology provided a fast and economic method for instrument self testing system. It also established a brand new method to improve instrument's detection performance.Numerous technological innovation and renewal such as fashion design, element lamp multi-dimensional automatic adjustment system,gas path electronics functional and modular design,No-adjustment D-lamp holder and so on. SP-3800 series atomic absorption spectrophotometer SP-3801 Flame AAS SP-3802 Graphite Furnace AAS. SP-3803 Flame&Graphite Furnace AAS. Products Type SP-3801 Flame AAS SP-3802 Graphite Furnace AASSP-3803 Flame&Graphite Furnace AASMain Parameter Optical System Instrument Type: Single Beam Reflection Achromatic Optics SystemMonochrometer: Achromatic C-T ,Focus 350mmDispersion elements: grating system 1200line/mm characterization area 40×40mm2scintillation wavelength: 250nmBandwidth: 0.1,0.2,0.7,1.4mm AdjustableWavelength Range:190-900Wavelength Accuracy: ±0.2Wavelength Repeatability: ≤0.1nmResolution: Mn 3lines(279.5&279.8 Peak and Vally ≤30% Spectrophotometric Properties Measurement: A,T,CPhotometric Range: 0-125%,-0.1-3.00AStatic Baseline Drift: (Cu)±0.003A/30minDynamic Baseline Drift: (Cu)±0.006A/30minBackground Correction: D-Lamp Background Correction >50times Correction Ability(1Abs)Flame Characteristic Concentration:(Cu)≤0.025ug/mlDetection limit:(Cu)≤0.004ug/mlPrecision RSD:≤0.6%Burner: titaniumNebulizer: high-efficient nebulizerSpray chamber :anticorrosion materialSafety measures: Flame fuel gas, power assisted gas abnormal pressure protectionGraphite Furnace Characteristic quantity: Characteristic value (Cd≤0.5pg, Cu≤20pg)Detection Limit : Cd≤0.8 pgPrecision: Cd , Cu≤ 4%Temperature Range: Room-temperature 3000°CHigh-Power Heating Range: 1500°C 3000°CRamp time & Holding time: 1s 255sHeating Rate: Max Heating Rate 2000°C/SAtomization Heating: Optical Control, Time Control, NormalProtect Gas Flow Rate our of Graphite Tube: 1 L/minProtect Gas Flow Rate in Graphite Tube: 0-50ml/min micro-flow,300-400ml/min Fixed-FlowSafety measures: Cooling water flow, Protect Gas Pressure, furnace temperature ,Graphite Tube AlarmData Process Test Manner: Flame, Graphite Furnace, hydride-AA, flame emissionConcentration: standard curve, standard addition, interpolationTimes of repetitive measurement:1-30times Average Value of A&CReport Print:parameters, data result